Heres info on my environment
XP pro, mqseries client 5.1
Os/390 2.1 mqsersies 5.3
I am trying to send a pdf as the content of a mq message
from NT to os/390, a os/390 process needs to pick the message up unconverted. The
problem is some characters are getting converted in the
:
Sent by: Subject: problem send binary message nt
os/390 #2
MQSeries List
MQSERIES@AKH-Wi
: Wednesday, January 15, 2003 9:55 AM
To: [EMAIL PROTECTED]
Subject: Re: problem send binary message nt os/390 #2
You could try setting the CCSID in the message to that of your QMGR on
OS/390. When MQ sees that the there's no difference in the CCSID, it
should bypass any conversion attempts
But Deborah specifically said that the message format was set to MQFMT_NONE
(well actually she said blank, but that's the same), so no conversion should
apply. I suspect some form of application error reading or writing the
file (e.g. file read as text rather than binary).
Dave
Instructions
]
COM cc:
Sent by: MQSeriesSubject: problem send binary message
nt os/390 #2
List