RE: ATM SVCs/Signalling

2003-03-21 Thread Mark Borchers
Will go off list with any subsquent Q&A, but here is the further detail on the architecture: > 1. What manufacturer of the devices and what model are the edge and then > the network device you are connecting to? Using Marconi 200ASX connecting to transit provider's Fore/Marconi switch (don't kn

Re: ATM SVCs/Signalling

2003-03-21 Thread John L Lee
Mark, 1. What manufacturer of the devices and what model are the edge and then the network device you are connecting to? 2. What version and revision of UNI (3.1,4.0) is your edge device using? UNI 3.0 is PVC, UNI 3.1 is original SVC support, UNI 4.0, 4.1 if it is out yet is more advnaced SVC.

ATM SVCs/Signalling

2003-03-21 Thread Mark Borchers
Good morning, I'm working on a project that requires the use of ATM SVCs through a large PNNI cloud. My equipment sits on the edges of the cloud. It appears that static NSAP routes configured on one of the upstream edge switches is being intermittently withdrawn (or blocked). Are there any oper