--On 20 September 2004 10:50 -0700 Philip Lavine <[EMAIL PROTECTED]>
wrote:
More clues. It seems that everytime I ping with the
pattern the controller counter:
rx_soft_overrun_err=27473, increments.
If you admin both ends, enable scrambling.
Alex
3 or M13/M23 vs CBIT.
>
> -Original Message-
> From: [EMAIL PROTECTED]
> [mailto:[EMAIL PROTECTED] On Behalf Of
> Philip Lavine
> Sent: Monday, September 20, 2004 1:26 PM
> To: nanog
> Subject: Re: HSSI-adtran
>
>
> To all,
>
> I tried
To all,
I tried the attenuator and they failed to provide any
relief.
Philip
--- Alex Bligh <[EMAIL PROTECTED]> wrote:
>
>
>
> --On 20 September 2004 07:56 -0700 Philip Lavine
> <[EMAIL PROTECTED]>
> wrote:
>
> > I am having a problem witha DS3 that terminates
> into a
> > Adtran CSU (T3S
--On 20 September 2004 07:56 -0700 Philip Lavine <[EMAIL PROTECTED]>
wrote:
I am having a problem witha DS3 that terminates into a
Adtran CSU (T3SU-300) and then into a 7200 with HSSI.
I can not ping with a data pattern and I
experience packet loss and errors when I pass TCP
traffic.
Adtran