Re: [PATCH net] be2net: avoid vxlan offloading on multichannel configs

2015-08-17 Thread David Miller
From: Ivan Vecera Date: Fri, 14 Aug 2015 22:30:01 +0200 > VxLAN offloading is not functional if the NIC is running in multichannel > mode (UMC, FLEX-10, VNIC...). Enabling this additionally kills whole > connectivity through the NIC and the device needs to be down and up to > restore it. The firm

Re: [PATCH net] be2net: avoid vxlan offloading on multichannel configs

2015-08-14 Thread Ajit Kumar Khaparde
> On Aug 14, 2015, at 3:30 PM, Ivan Vecera wrote: > > VxLAN offloading is not functional if the NIC is running in multichannel > mode (UMC, FLEX-10, VNIC...). Enabling this additionally kills whole > connectivity through the NIC and the device needs to be down and up to > restore it. The firmwar

[PATCH net] be2net: avoid vxlan offloading on multichannel configs

2015-08-14 Thread Ivan Vecera
VxLAN offloading is not functional if the NIC is running in multichannel mode (UMC, FLEX-10, VNIC...). Enabling this additionally kills whole connectivity through the NIC and the device needs to be down and up to restore it. The firmware should take care about it and does not allow the conversion o