Re: [PATCH v2 3/3] net/phy: micrel: Center FLP timing at 16ms

2015-06-05 Thread Jaeden Amero
On 06/05/2015 04:09 PM, Sergei Shtylyov wrote: >> @@ -441,6 +461,7 @@ static int ksz9031_config_init(struct phy_device >> *phydev) >> "txd2-skew-ps", "txd3-skew-ps" >> }; >> static const char *control_skews[2] = {"txen-skew-ps", >> "rxdv-skew-ps"}; >> +int result; > >

Re: [PATCH v2 3/3] net/phy: micrel: Center FLP timing at 16ms

2015-06-05 Thread Sergei Shtylyov
Hello. On 06/05/2015 10:55 PM, Jaeden Amero wrote: Link failures have been observed when using the KSZ9031 with HP 1810-8G and HP 1910-8G network switches. Center the FLP timing at 16ms to help avoid intermittent link failures. From the KSZ9031RNX and KSZ9031MNX data sheets revision 2.2, se

[PATCH v2 3/3] net/phy: micrel: Center FLP timing at 16ms

2015-06-05 Thread Jaeden Amero
Link failures have been observed when using the KSZ9031 with HP 1810-8G and HP 1910-8G network switches. Center the FLP timing at 16ms to help avoid intermittent link failures. >From the KSZ9031RNX and KSZ9031MNX data sheets revision 2.2, section "Auto-Negotiation Timing": The KSZ9031[RNX