Re: [nox-dev] When will datapath leave network?

2010-02-19 Thread Guanyao Huang
The error messsages below are for the HP virtual switches. The NEC switch does leave the network, but shows flow table is full. On Fri, Feb 19, 2010 at 5:17 PM, Guanyao Huang wrote: > Hello > I am running on a topology of 9 switches. It uses both HP switch and > NEC switch. What is the meaning of

Re: [nox-dev] When will datapath leave network?

2010-02-19 Thread Martin Casado
It looks to me like the switch is closing the connection, not the controller. So this is probably a question for HP ... ? Hello I am running on a topology of 9 switches. It uses both HP switch and NEC switch. What is the meaning of the following error? Is it the controller connection breaking

[nox-dev] When will datapath leave network?

2010-02-19 Thread Guanyao Huang
Hello I am running on a topology of 9 switches. It uses both HP switch and NEC switch. What is the meaning of the following error? Is it the controller connection breaking out? When this occurs, I remember the number of entries is less than 1500, actually around 800 for HP. What are the possible r