Re: [Nut-upsuser] [EXTERNAL] Re: Tripp Lite SMART1500LCD will not stay shut down when power is disconnected

2020-01-14 Thread David Zomaya
Thanks Layne. Ball is in my court to get back to both of you. Feel free to nudge me if I don't update in a week or so. From: Layne Fowler Sent: Tuesday, January 14, 2020 11:47:01 PM To: David Zomaya Cc: Ken Olum; nut-upsuser@alioth-lists.debian.net Subject: Re: [

Re: [Nut-upsuser] [EXTERNAL] Re: Tripp Lite SMART1500LCD will not stay shut down when power is disconnected

2020-01-14 Thread Layne Fowler
My serial # is 2835BY0SM886900639, model # SMART1500LCD. Using stock nut, my UPS will turn back on after load off, even with no power connected. Servers boot up and fail when the UPS finally dies. Using my patched nut, the UPS will fail to turn on if the power returns after the shutdown command b

Re: [Nut-upsuser] [EXTERNAL] Re: Tripp Lite SMART1500LCD will not stay shut down when power is disconnected

2020-01-14 Thread David Zomaya
Thanks Ken. I'll plan to sit down and look up the protocol information over the next week or so and follow up. From: Ken Olum Sent: Tuesday, January 14, 2020 1:35:10 PM To: David Zomaya Cc: k...@cosmos.phy.tufts.edu; layne.fow...@gmail.com; nut-upsuser@alioth-lis

Re: [Nut-upsuser] [EXTERNAL] Re: Tripp Lite SMART1500LCD will not stay shut down when power is disconnected

2020-01-14 Thread David Zomaya
If you'd like, shoot me over your serial number and the corner-cases you don't have answers for and I can look into it. Thank you, David Zomaya Tripp Lite david_zom...@tripplite.com -Original Message- From: Nut-upsuser On Behalf Of Ken Olum Sent: Tuesday, January 14, 2020 11:24 AM To