Hi,
We've got various Juniper devices with links that have FEC enabled and
CLI output shows the FEC stats, but I don't see them anywhere in
Observium.
Is this not supported or am I missing something to where it's at /
what is it called?
Thanks
___
obse
I’d say before changing maxreps go to the device and go to the
gear-->Performance data and see which module(s) are taking the longest.
If they’re ones you don’t care about you can disable them for that device.
Spencer J. Ryan| Manager, Technology and Infrastructu
These ASA’s do not have many interfaces at all, about 10 and some are near,
while others are far…but all take between 50 and 60 seconds to poll. By
contrast, my 48 ports switches take about 8 sec.
I think there must be something else about them that is different
Tony Guadagno
O +1 585 577 100
This can happen when a device has a large number of interfaces and/or the
device is a long way away (ping time).
Also, the snmp poller only collects 10 items at a time which is
compatible with everything.
However some devices can handle collecting many more items at a time.
Go into Device Properti
Hi, I am just noticing that my Cisco ASA's poll really slow. While all my
other infrastructure seems to poll about 5 to 7 sec per device, the ASA's all
take 50 to 60 sec.
Does anyone know why this is and maybe how to speed things up?
Thanks
Tony Guadagno
O +1 585 577 1003
C +1 585 703 6700
E