** [tickets:#978] PLM: admin reset of HE with no EE never returns**
**Status:** accepted
**Milestone:** 4.5.FC
**Created:** Tue Aug 05, 2014 07:35 PM UTC by Alex Jones
**Last Updated:** Tue Aug 05, 2014 07:35 PM UTC
**Owner:** Alex Jones
If an HE doesn't have an EE, the admin reset for th
- **status**: accepted --> review
---
** [tickets:#977] PLM: standby plm server should wait until contact with HPI
has been established before finishing init**
**Status:** review
**Milestone:** 4.5.FC
**Created:** Tue Aug 05, 2014 03:08 PM UTC by Alex Jones
**Last Updated:** Tue Aug 05, 2014
---
** [tickets:#977] PLM: standby plm server should wait until contact with HPI
has been established before finishing init**
**Status:** accepted
**Milestone:** 4.5.FC
**Created:** Tue Aug 05, 2014 03:08 PM UTC by Alex Jones
**Last Updated:** Tue Aug 05, 2014 03:08 PM UTC
**Owner:** Alex Jon
- **status**: review --> fixed
- **Comment**:
changeset: 5529:dd763c8fd23e
tag: tip
user:Lennart Lund
date:Tue Aug 05 15:38:18 2014 +0200
summary: log: New testcases for testing max length handling of SaNameT
[#891]
rev: dd763c8fd23e6a9d5168874dc6d59901e3a26239
ch
In The above post SaImmClassNameT is overlooked as SaNameT.
Above post is not valid.
---
** [tickets:#643] IMM: API that replaces SaNameT with SaStringT and
SA_IMM_ATTR_DN**
**Status:** assigned
**Milestone:** 4.6.FC
**Created:** Thu Nov 28, 2013 05:00 PM UTC by Anders Bjornerstedt
**Last Upd
saImmOmClassDescriptionGet_2 which has SaNameT parameter is missing in the
attached P643.api.
---
** [tickets:#643] IMM: API that replaces SaNameT with SaStringT and
SA_IMM_ATTR_DN**
**Status:** assigned
**Milestone:** 4.6.FC
**Created:** Thu Nov 28, 2013 05:00 PM UTC by Anders Bjornerstedt
*
There is one more problem. safSg=2N,safApp=OpenSAF remain in 2 and when SC-1
joins it doesn't assign SI to safSu=SC-1,safSg=2N,safApp=OpenSAF.
---
** [tickets:#708] Standby Controller failed to come up when failover happened
in the middle of switchover**
**Status:** accepted
**Milestone:**
- **status**: assigned --> not-reproducible
---
** [tickets:#707] Quiesced controller failed to become Active when the standby
controller rebooted in middle of switchover**
**Status:** not-reproducible
**Milestone:** 4.3.3
**Created:** Fri Jan 03, 2014 03:34 PM UTC by Sirisha Alla
**Last Upda
RDE Recived 3 role sets and this resulted in the issue.
Case 1:
Jan 3 14:42:09 SLES-64BIT-SLOT2 osafrded[2375]: NO rde_rde_set_role: role set
to 1
Jan 3 14:42:09 SLES-64BIT-SLOT2 osafrded[2375]: NO rde_rde_set_role: role set
to 1
Jan 3 14:42:14 SLES-64BIT-SLOT2 osafrded[2375]: NO rde_rde_set
- **status**: assigned --> accepted
---
** [tickets:#708] Standby Controller failed to come up when failover happened
in the middle of switchover**
**Status:** accepted
**Milestone:** 4.3.3
**Created:** Fri Jan 03, 2014 03:48 PM UTC by Sirisha Alla
**Last Updated:** Tue Aug 05, 2014 10:51 AM
Logs attached is not from "Jan 3".
Analyzed based on logs attached in #707 as similar problem has been observed in
#707 in some instances:
Jan 3 16:12:01 SLES-64BIT-SLOT1 osafamfnd[2948]: Started
Jan 3 16:44:01 SLES-64BIT-SLOT1 opensafd[2818]: ER Timed-out for response from
AMFND
Jan 3 16:44:0
- **status**: assigned --> duplicate
- **Milestone**: 4.3.3 --> never
- **Comment**:
The problem of invalid configuration (more CSIs and less components) got fixed
in #856. Attached are the logs after successful verification on default branch.
Closing this ticket as duplicate of #856.
---
*
12 matches
Mail list logo