Re: [openstack-dev] [ceilometer][nova] extra Ceilometer Samples of the instance gauge

2014-08-04 Thread Qiming Teng
Regarding the intevals, it can be configured in your pipeline.yaml file. e.g. sources: - name: meter_source interval: 600 <-- change this to a smaller one if you like meters: - "*" sinks: - meter_sink Regards, - Qiming On Wed, Jul 30, 2014 at 02:16:

Re: [openstack-dev] [ceilometer][nova] extra Ceilometer Samples of the instance gauge

2014-07-30 Thread gordon chung
> In a normal DevStack install, each Compute instance causes one Ceilometer > Sample every 10 minutes. Except, there is an extra one every hour. And a > lot of extra ones at > the start. What's going on here? instance is one meter which is generated through both polling and notifications (se

[openstack-dev] [ceilometer][nova] extra Ceilometer Samples of the instance gauge

2014-07-30 Thread Mike Spreitzer
In a normal DevStack install, each Compute instance causes one Ceilometer Sample every 10 minutes. Except, there is an extra one every hour. And a lot of extra ones at the start. What's going on here? For example: $ ceilometer sample-list -m instance -q resource=9108b64e-0e30-45fa-9fdf-ccc2