On Wed, Apr 13, 2022 at 2:36 AM Han Zhou wrote:
>
> On Mon, Apr 11, 2022 at 2:05 PM Numan Siddique wrote:
> >
> > On Sat, Feb 5, 2022 at 12:12 AM Han Zhou wrote:
> > >
> > > On Fri, Feb 4, 2022 at 7:58 AM Mark Michelson
> wrote:
> > > >
> > > > As far as I can tell, this looks correct.
> > > >
On Mon, Apr 11, 2022 at 2:05 PM Numan Siddique wrote:
>
> On Sat, Feb 5, 2022 at 12:12 AM Han Zhou wrote:
> >
> > On Fri, Feb 4, 2022 at 7:58 AM Mark Michelson
wrote:
> > >
> > > As far as I can tell, this looks correct.
> > >
> > > Acked-by: Mark Michelson
> >
> > Thanks Mark. I applied it to
On Sat, Feb 5, 2022 at 12:12 AM Han Zhou wrote:
>
> On Fri, Feb 4, 2022 at 7:58 AM Mark Michelson wrote:
> >
> > As far as I can tell, this looks correct.
> >
> > Acked-by: Mark Michelson
>
> Thanks Mark. I applied it to the main branch.
Hi Han,
We have an issue in OVN 21.12 (and OVN 21.09) w
On Fri, Feb 4, 2022 at 7:58 AM Mark Michelson wrote:
>
> As far as I can tell, this looks correct.
>
> Acked-by: Mark Michelson
Thanks Mark. I applied it to the main branch.
>
> On 1/20/22 13:06, Han Zhou wrote:
> > For I-P node lflow_output, different change handlers can trigger
> > reprocessin
As far as I can tell, this looks correct.
Acked-by: Mark Michelson
On 1/20/22 13:06, Han Zhou wrote:
For I-P node lflow_output, different change handlers can trigger
reprocessing lflows. However, it is a waste to reprocess the same lflow
multiple times in the same run, because each processing
For I-P node lflow_output, different change handlers can trigger
reprocessing lflows. However, it is a waste to reprocess the same lflow
multiple times in the same run, because each processing of the lflow is
against the same input data.
For example, if a lflow references an addresset A and a port