Re: [ovs-dev] [PATCH ovn v2] northd: Update the probe interval in main loop.

2021-09-21 Thread Han Zhou
On Tue, Sep 21, 2021 at 11:08 AM Zhen Wang wrote: > > From: zhen wang > > When ovn-northd work in HA mode, ovn-northd will not update the > probe interval in standby mode. If SB/NB raft leader and active > ovn-northd instance got killed by system power outage, standby > ovn-northd instance would

[ovs-dev] [PATCH ovn v2] northd: Update the probe interval in main loop.

2021-09-21 Thread Zhen Wang via dev
From: zhen wang When ovn-northd work in HA mode, ovn-northd will not update the probe interval in standby mode. If SB/NB raft leader and active ovn-northd instance got killed by system power outage, standby ovn-northd instance would never detect the failure. This patch address the problem by