Can it be the CRC-bug in the 2.6p5 which also effected the voltage-readings
for DS2450?
Perhaps the new 2.6p6 will fix the problem.
/Christian
> -Original Message-
> From: [EMAIL PROTECTED] [mailto:owfs-
> [EMAIL PROTECTED] On Behalf Of [EMAIL PROTECTED]
> Sent: den 20 augusti 2007 01:
This seems to be my evening to blather. The function already exists. It's
called "defaultpmod".
defaultpmod reads/sets the default sleep mode bit.
Paul Alfille
-
This SF.net email is sponsored by: Splunk Inc.
Still grepping t
My apologies to Eric Vickery. His note above give the complete reference.
>From http://www.weathertoys.net/phpBB2/viewtopic.php?t=70
... Anyway the DS2760 starts out in a sleep mode and here is what you need
to do to get it out of sleep mode.
Connect up the Moisture Meter to the 1-Wire network an
On 8/19/07, [EMAIL PROTECTED] <[EMAIL PROTECTED]> wrote:
>
> That sounds likely to be what I'm facing. I've read the thread, but have
> no idea how to do this using the existing 1wire owfs software. I'll read
> up on it and see what I can come up with -- all I've done, so far, is
> shell access:
> Date: Sun, 19 Aug 2007 11:25:30 -0500
> From: Eric Vickery <[EMAIL PROTECTED]>
> Subject: Re: [Owfs-developers] DS2760 question
> To: owfs-developers@lists.sourceforge.net
> Message-ID: <[EMAIL PROTECTED]>
> Content-Type: text/plain; charset=ISO-8859-1; format=flowed
>
> John,
>
> It sounds like
> Message: 4
> Date: Sun, 19 Aug 2007 07:01:02 -0400
> From: "Paul Alfille" <[EMAIL PROTECTED]>
> Subject: Re: [Owfs-developers] DS2760 question
> To: owfs-developers@lists.sourceforge.net
> Message-ID:
> <[EMAIL PROTECTED]>
> Content-Type: text/plain; charset="iso-8859-1"
>
> Thanks for the
John,
It sounds like the DS2760 is in sleep mode. You can look at the thread
here http://www.weathertoys.net/phpBB2/viewtopic.php?t=70. It talks
about our Moisture Meter but is the same for any DS2760 based device.
Hope that helps.
Eric
www.hobby-boards.com
[EMAIL PROTECTED] wrote:
> So far,
Thanks for the report.
There isn't an obvious error in the temperature code for the DS2760. It's a
read of location 0x18-9 and simple conversion to the correct units.
Can you help me with a couple of other steps:
1. What version of OWFS are you using?
2. Can you read some of the other values -- l