It's an old board, the chip says 3610 (I think), and all readings are
coming in raw (over 100).
On 07/25/2013 12:15 PM, Eric Vickery wrote:
> I don't know if this is the issue but unless you have a very old humidity
> board then you should be getting the readings from the HIH4000 directory. The
I don't know if this is the issue but unless you have a very old humidity board
then you should be getting the readings from the HIH4000 directory. The HIH3600
and HIH4000 sensors use slightly different formula for calculating the humidity.
Eric
On Jul 25, 2013, at 10:32 AM, Rick Bolen(gm) wro
hello,
I recently compiled the latest source and am running owserver. My perl
script using OWNet.pm returns readings greater than 100 for humidity.
I read\print the following:
$owserver->read('/uncached/1F.AE4E0200/main/26.901F7400/HIH3600/humidity')
I read that, at some point, humidit