Am 05.09.2018 um 05:20 schrieb Matthias Urlichs via Owfs-developers:
> Hi,
>
> I'm writing a new high-level asynchronous Python library to talk
> to owserver.
>
> It features multiple persistent server connections, transparent
> support for DS2409 couplers, automatic retries when he server is
> b
On 04.09.2018 20:37, Loren Amelang wrote:
> I have a single bus with ten parasitic 18B20s spread along close to 100' of
> cable
Wow. Frankly I wouldn't even dream of doing that without a 5V wire.
My basement bus would have required close to twice that lenght if I had
run it as a single straight
Hi,
I'm writing a new high-level asynchronous Python library to talk to
owserver.
It features multiple persistent server connections, transparent support
for DS2409 couplers, automatic retries when he server is busy or the
connection breaks, object-oriented design, auto-generating accessor
method
hi Loren,
Le mardi 4 septembre 2018 à 21:00:45 UTC+2, Loren Amelang
a écrit :
> Another thing that helped was adding a 1N5711 Schottky diode and a
> 1.5KE20A-T TVS at each end of the> bus (it is driven from the middle).
It's for lightning protection ?If so, did you has close lightning
> Date: Tue, 4 Sep 2018 08:52:07 + (UTC)
> From: Laurent FAILLIE
>
> The capacitor has not to be put on the buses (otherwise, you will disturb
> 1-wire signals) but on the GND and Vcc pin of the DS2482-800.As far I
> remember, I've put a 0.1uF ... (not sure :) ). Bye
I have a single bus with
The capacitor has not to be put on the buses (otherwise, you will disturb
1-wire signals) but on the GND and Vcc pin of the DS2482-800.As far I remember,
I've put a 0.1uF ... (not sure :) ).
Bye
Le mardi 4 septembre 2018 à 10:41:33 UTC+2, Mick Sulley
a écrit :
Thanks for the reply
Thanks for the reply.
Yes the adapter is based upon the DS2482-800. What value of capacitor
and should it be at the adapter or the far end of the bus? Do I just
need one or one on each bus?
Thanks
Mick
On 04/09/18 00:22, Laurent FAILLIE via Owfs-developers wrote:
Hi,
If the "" is based