[Erik Freiholtz]
> My DS2450S based light sensors is powered and fails measuring voltages
> around 5V after a while. At the moment everything has been ok for a day
> or two.
I don't know if it's related, but I also have two DS2760's (Hobby
Boards moisture meters) which owfs sometimes gets readi
Steinar Midtskogen skrev:
> Paul Alfille writes:
>
>
>> Looking through the oww source code, it looks like they reset all the
>> parameters before every measurement. I wonder if the flaky sensors
>> have an intermittent connection and do unscheduled power-on-resets?
>>
>
> Is it easy to ad
Paul Alfille writes:
> Looking through the oww source code, it looks like they reset all the
> parameters before every measurement. I wonder if the flaky sensors
> have an intermittent connection and do unscheduled power-on-resets?
Is it easy to add the reset in owserver as well? I'll gladly tr
Looking through the oww source code, it looks like they reset all the
parameters before every measurement. I wonder if the flaky sensors
have an intermittent connection and do unscheduled power-on-resets?
Paul Alfille
On Mon, Jul 13, 2009 at 3:37 AM, Matthias Urlichs wrote:
> Hi,
>
> Steinar Midt
Hi,
Steinar Midtskogen:
> Both anemometers work fine in oww, but only one of the works in owfs.
Strange. I have one of those, too; it goes offline when the ambient
temperature rises beyond 25°C or so. :-/
--
Matthias Urlichs | {M:U} IT Design @ m-u-it.de | sm...@smurf.noris.de
Disclaimer:
[Jan Kandziora]
> Am Freitag, 10. Juli 2009 schrieb Steinar Midtskogen:
>> None of the anemometers have external power.
>>
> Simultaneous conversion is not possible when on parasitic power. That's a
> limitation of the hardware. If OWW works, it just doesn't use simultaneous
> conversion.
I'm n
I have similar problems with DS2450.
I have 3 DS2450S connected to my network (CO2-level, Barometric preasure
and a Light sensor). On two of the chips I measure the VDD level on my
network.
On one of the chips (always the same) I get 0V as a result when
measuring the VDD level (that is approx
Am Freitag, 10. Juli 2009 schrieb Steinar Midtskogen:
> None of the anemometers have external power.
>
Simultaneous conversion is not possible when on parasitic power. That's a
limitation of the hardware. If OWW works, it just doesn't use simultaneous
conversion.
Kind regards
Jan
--
".
Paul Alfille writes:
> So one DS2405 works well, and the other not?
You mean DS2450? Both work in oww, but only one works in owfs. So it
looks like the adc stuff in owfs has a problem.
-Steinar
>
> Paul Alfille
>
> On Fri, Jul 10, 2009 at 8:21 AM, Steinar
> Midtskogen wrote:
>> I have two A
So one DS2405 works well, and the other not?
Paul Alfille
On Fri, Jul 10, 2009 at 8:21 AM, Steinar
Midtskogen wrote:
> I have two AAG anemometers, both DS2450 based. Eight reed switches
> are organised in such a way that each of the four inputs to the AD
> converter either is (roughly) 0V, 2.5V
I have two AAG anemometers, both DS2450 based. Eight reed switches
are organised in such a way that each of the four inputs to the AD
converter either is (roughly) 0V, 2.5V or 5V and the combination of
the four levels will identify one of 16 bearings of the vane (whose
magnet will connect the swit
11 matches