Hi,
is there any online training provided by clusterlabs?
tnx
miha
___
Pacemaker mailing list: Pacemaker@oss.clusterlabs.org
http://oss.clusterlabs.org/mailman/listinfo/pacemaker
Project Home: http://www.clusterlabs.org
Getting started: http
tnx!
will do that and let you know.
miha
Dne 8/20/2014 5:03 PM, piše emmanuel segura:
Hi,
You need to give every cluster parameter to the
fence_bladecenter_snmp, so from sp2 you neet to use " Attributes:
action=off ipaddr=172.30.0.2 port=8 community=test login=snmp8
passwd=sof
ok, will do that. This will not affect sip2?
sorry for my noob question but I must be careful as this is in production ;)
So, "fence_bladecenter_snmp reboot" right?
br
miha
Dne 8/19/2014 11:53 AM, piše emmanuel segura:
sorry,
That was a typo, fixed "try to poweroff sp1 by
hi,
what do you mean by "by had of powweroff sp1"? do power off server sip1?
One thing also bothers me. Why on sip2 cluster service is not running if
still virual ip and etc are all properly running?
tnx
miha
Dne 8/19/2014 9:08 AM, piše emmanuel segura:
Your config look ok, have
sorry, here is it:
br
miha
Dne 8/18/2014 11:33 AM, piše emmanuel segura:
your cman /etc/cluster/cluster.conf ?
2014-08-18 7:08 GMT+02:00 Miha
Properties:
cluster-infrastructure: cman
dc-version: 1.1.10-14.el6-368c726
no-quorum-policy: ignore
stonith-enabled: true
Node Attributes:
sip1: standby=off
sip2: standby=off
br
miha
Dne 8/14/2014 3:05 PM, piše emmanuel segura:
ncomplete=10, Source=/var/lib/pacemaker/pengine/pe-warn-7.bz2
emmanuel,
tnx. But how to know why fancing stop working?
br
miha
Dne 8/14/2014 2:35 PM, piše emmanuel segura:
Node sip2: UNCLEAN (offline) is unclean because the cluster fencing
failed to complete the operation
2014-08-14 14:13 GMT+02:00 Miha :
hi.
another thing.
On node I pcs is running
(stonith:fence_bladecenter_snmp): Started sip2
[root@sip1 ~]#
Dne 8/14/2014 2:12 PM, piše Miha:
Hi emmanuel,
i think so, what is the best way to check?
Sorry for my noob question, I have confiured this 6 mouths ago and
everything was working fine till now. Now I need to find out what
realy heppend
you sure your cluster fencing is working?
2014-08-14 13:40 GMT+02:00 Miha :
Hi,
I noticed today that I am having some problem with cluster. I noticed the
master server is offilne but still virutal ip is assigned to it and all
services are running properly (for production).
If I do this I am
:25 fenced cman_get_cluster error -1 112
The main thing is what to do now? Do "pcs start" and hope for the best
or what?
I have pasted log in pastebin: http://pastebin.com/SUp2GcmN
tnx!
miha
___
Pacemaker mailing list: Pacemaker@oss.clust
HI,
I did but I am getting:
[root@sip2 ~]# crm history resource p_mysql
INFO: retrieving information from cluster nodes, please wait ...
/bin/sh: hb_report: command not found
ERROR: live: hb_report failed
[root@sip2 ~]
br,
miha
Dne 11/22/2013 10:19 AM, piše Lars Marowsky-Bree:
On 2013-11
Hi Andrew,
here is my config:
http://pastebin.com/rU7ikudg
Stonith is not configured yet as I am waiting for some info
from IBM support as I am needing it regarding IMPI.
Thx!
MIha
On Fri, 22 Nov 2013 09:50:50 +1100
Andrew Beekhof wrote:
>
> On 22 Nov 2013, at 7:32 am, Miha
2013',
queued=33ms, exec=0ms
p_mysql_monitor_0 on sip1 'not installed' (5): call=22,
status=complete, last-rc-change='Thu Nov 21 15:26:52 2013',
queued=36ms, exec=0ms
Mysql is running, drive is mounted, and in mysql there is
no errors.
tnx!
miha
___
HI,
how can i delete/reset all config, so that I could do again:
*'pcs cluster setup mycluster pcmk-1 pcmk-2'* and begin again at the
beginning?
tnx!
p.s.: bellowe is a log
Nov 21 11:51:21 [10578] sip1cib:error: xml_log: Expecting
element status, got node_state
Nov 21 11:51:21 [
HI Andrew,
tnx for replay.
I have fixed this. It was missconfiguration with cluster name. It was
different on bouth nodes.
br,
miha
Dne 11/19/2013 4:28 AM, pis(e Andrew Beekhof:
On 18 Nov 2013, at 11:59 pm, Miha wrote:
HI,
I am for the first time setting cluster with pacemaker
onith_notify: Peer
sip1.domain.com was not terminated (reboot) by sip2.domain.com for
sip2.domain.com: No such device
(ref=64a4294f-059a-416f-8e9d-944db759a0e6) by client
stonith_admin.cman.18287
Nov 18 21:36:42 sip2 fence_pcmk[18286]: Call to fence sip1.domain.com
(reset) failed with rc=23
16 matches
Mail list logo