Re: [Pacemaker] OCFS2 fails to mount file system on node reboot sometimes

2011-03-09 Thread Jake Smith
"Jake Smith" Sent: Wednesday, March 9, 2011 3:54:27 AM Subject: Re: [Pacemaker] OCFS2 fails to mount file system on node reboot sometimes On Tue, Feb 22, 2011 at 7:56 PM, Jake Smith wrote: > I get the following error after reboot sometimes when mounting the ocfs2 > file sy

Re: [Pacemaker] OCFS2 fails to mount file system on node reboot sometimes

2011-03-09 Thread Andrew Beekhof
On Tue, Feb 22, 2011 at 7:56 PM, Jake Smith wrote: > I get the following error after reboot sometimes when mounting the ocfs2 > file system.  If I manually stop and restart corosync it mounts fine but if > I just try to run cleanup or crm resource start it fails.  I don't > understand how I am get

[Pacemaker] OCFS2 fails to mount file system on node reboot sometimes

2011-02-22 Thread Jake Smith
I get the following error after reboot sometimes when mounting the ocfs2 file system. If I manually stop and restart corosync it mounts fine but if I just try to run cleanup or crm resource start it fails. I don't understand how I am getting no local IP address set when both the bonded links for