Re: [Pacemaker] clmvd hangs on node1 if node2 is fenced

2010-08-30 Thread Rainer
Michael Smith writes: > I've got a pair of fully patched SLES11 SP1 nodes and they're showing > what I guess is the same behaviour: if I hard-poweroff node2, operations > like "vgdisplay -v" hang on node1 for quite some time. Sometimes a > minute, sometimes two, sometimes forever. They get stu

Re: [Pacemaker] clmvd hangs on node1 if node2 is fenced

2010-08-27 Thread Michael Smith
Tim Serong wrote: On 8/27/2010 at 03:37 PM, Michael Smith wrote: I think I'd consider it a bug: I've disabled stonith, so dlm shouldn't wait forever for a fence operation that isn't going to happen. I reckon if you set the args parameter of your ocf:pacemaker:controld resource to "-f 0 -

Re: [Pacemaker] clmvd hangs on node1 if node2 is fenced

2010-08-27 Thread Tim Serong
On 8/27/2010 at 03:37 PM, Michael Smith wrote: > On Thu, 26 Aug 2010, Tim Serong wrote: > > > > for now I have stonith-enabled="false" in > > > my CIB. Is there a way to make clvmd/dlm respect it? > > > > No. At least, I don't think so, and/or I hope not :) > > I think I'd consider

Re: [Pacemaker] clmvd hangs on node1 if node2 is fenced

2010-08-26 Thread Michael Smith
On Thu, 26 Aug 2010, Tim Serong wrote: > > for now I have stonith-enabled="false" in > > my CIB. Is there a way to make clvmd/dlm respect it? > > No. At least, I don't think so, and/or I hope not :) I think I'd consider it a bug: I've disabled stonith, so dlm shouldn't wait forever for a fe

Re: [Pacemaker] clmvd hangs on node1 if node2 is fenced

2010-08-26 Thread Tim Serong
On 8/27/2010 at 01:49 PM, Michael Smith wrote: > On Thu, 26 Aug 2010, Tim Serong wrote: > > > > Aug 26 18:31:51 xen-test1 cluster-dlm[8870]: fence_node_time: Node > > > 236655788/xen-test2 has not been shot yet > > > Do you have STONITH configured? Note that it says "xen-test2 has not

Re: [Pacemaker] clmvd hangs on node1 if node2 is fenced

2010-08-26 Thread Michael Smith
On Thu, 26 Aug 2010, Tim Serong wrote: > > Aug 26 18:31:51 xen-test1 cluster-dlm[8870]: fence_node_time: Node > > 236655788/xen-test2 has not been shot yet > Do you have STONITH configured? Note that it says "xen-test2 has not > been shot yet" and "clvmd ... not fenced". It's just going to si

Re: [Pacemaker] clmvd hangs on node1 if node2 is fenced

2010-08-26 Thread Tim Serong
On 8/27/2010 at 08:50 AM, Michael Smith wrote: >> Xinwei Hu writes: > > > > > That sounds worrying actually. > > > I think this is logged as bug 585419 on SLES' bugzilla. > > > If you can reproduce this issue, it worths to reopen it I think. > > I've got a pair of fully patched SLES11

Re: [Pacemaker] clmvd hangs on node1 if node2 is fenced

2010-08-26 Thread Michael Smith
> Xinwei Hu writes: > > > That sounds worrying actually. > > I think this is logged as bug 585419 on SLES' bugzilla. > > If you can reproduce this issue, it worths to reopen it I think. I've got a pair of fully patched SLES11 SP1 nodes and they're showing what I guess is the same behaviour: if

Re: [Pacemaker] clmvd hangs on node1 if node2 is fenced

2010-08-26 Thread Michael Smith
Xinwei Hu writes: > 2010/8/16 Rainer Lutz : > > Xinwei Hu writes: > >> This sounds a like a fixed issue for SLE11SP1 indeed. > > Well it is not fixed with SP1, but with some Patch after SP1 - don`t know > > which thou, as the clvmd is the same for SP1 before and after Online > > Patches. > T

Re: [Pacemaker] clmvd hangs on node1 if node2 is fenced

2010-08-16 Thread Xinwei Hu
2010/8/16 Rainer Lutz : > Xinwei Hu writes: > >> >> This sounds a like a fixed issue for SLE11SP1 indeed. >> referring to: >> http://archives.free.net.ph/message/20100309.075255.baa4b2eb.en.html >> > > Well it is not fixed with SP1, but with some Patch after SP1 - don`t know > which > thou, as th

Re: [Pacemaker] clmvd hangs on node1 if node2 is fenced

2010-08-16 Thread Rainer Lutz
Xinwei Hu writes: > > This sounds a like a fixed issue for SLE11SP1 indeed. > referring to: > http://archives.free.net.ph/message/20100309.075255.baa4b2eb.en.html > Well it is not fixed with SP1, but with some Patch after SP1 - don`t know which thou, as the clvmd is the same for SP1 before and

Re: [Pacemaker] clmvd hangs on node1 if node2 is fenced

2010-08-15 Thread Xinwei Hu
This sounds a like a fixed issue for SLE11SP1 indeed. referring to: http://archives.free.net.ph/message/20100309.075255.baa4b2eb.en.html 2010/8/15 Rainer Lutz : >> Any Idea how to solve it? > > I created a testscenario with the same conditions ( same OS Sles11 SP1 with > HAE > and the CIB from th

Re: [Pacemaker] clmvd hangs on node1 if node2 is fenced

2010-08-15 Thread Rainer Lutz
> Any Idea how to solve it? I created a testscenario with the same conditions ( same OS Sles11 SP1 with HAE and the CIB from the original cluster ), but with full online update and there everthing works fine. So it seems there was a bugfix for that. On Monday i will try a full update for my orig

[Pacemaker] clmvd hangs on node1 if node2 is fenced

2010-08-13 Thread Rainer
Hi, i have a strange problem. I am using a cloned dlm-clvm as mentioned in the sles11 hae guide. But when one of my node is fenced by the other - the surving node fails on its volumes because vgscan runs till EOF of CLVMD Any Idea how to solve it? Kind regards, Rainer _