[Paraview] display bonds between atoms using paraview

2013-10-03 Thread Jian Luo
t; > > > > > David E DeMarle > > Kitware, Inc. > > R&D Engineer > > 21 Corporate Drive > > Clifton Park, NY 12065-8662 > > Phone: 518-881-4909 > > > > > > > > On Wed, Sep 25, 2013 at 10:34 PM, Andy Bauer > >

Re: [Paraview] Null Scalar Value

2013-10-03 Thread Moreland, Kenneth
Can you put a NaN value in these points? -Ken From: Léo Pessanha mailto:leonardopessanh...@gmail.com>> Date: Thursday, October 3, 2013 12:35 PM To: "paraview@paraview.org" mailto:paraview@paraview.org>> Subject: [EXTERNAL] [Paraview] Null Scalar Value I think it`s

Re: [Paraview] NEK5000 with ParaView

2013-10-03 Thread Patrick O'Leary
Dear Matteo, NEK5000 file series is not supported in ParaView 3.98. This feature was added in the Spring of 2013 and is available in ParaView 4.0. Are you able to update to the current release? Regards, Patrick On Wed, Oct 2, 2013 at 9:44 AM, Matteo Righi wrote: > Dear all, > I'm trying to us

[Paraview] Null Scalar Value

2013-10-03 Thread Léo Pessanha
I think it`s a simple question... I have a scalar value(point_data) between -0.5 and 0.5 in vtk format files I have some points without information I would like to put something like '' NULL '' value in this points, but i can`t seem to find a way I`ve tried 0 but its in the range of the inform

Re: [Paraview] My own filter as part of pipeline for coprocessing raises "name not defined" error

2013-10-03 Thread Andy Bauer
Hmm, I would check the link line for your adaptor and for creating the executable to see if the plugin library is included there. Something else you can try is explicitly create the plugin's filter in the adaptor code to make sure that it is linked in properly. Regards, Andy On Thu, Oct 3, 2013

Re: [Paraview] My own filter as part of pipeline for coprocessing raises "name not defined" error

2013-10-03 Thread Hong Yi
Hi Andy, That is exactly what I did, and I also modified CMakeLists.txt to link ${PARAVIEW_PLUGINLIST} to the target via target_link_libraries. However, the symbol "pv_plugin_instance_SMVorticity" is undefined in the built target static library, while following the same process to build pvbatc

Re: [Paraview] My own filter as part of pipeline for coprocessing raises "name not defined" error

2013-10-03 Thread Andy Bauer
Hi Hong, There won't be a separate library created for Python wrapping your plugin for doing ParaView. Did you add in the following to your adaptor: #ifndef BUILD_SHARED_LIBS #include "pvStaticPluginsInit.h" #endif And then in the adaptor initialization step you should have something in it like:

[Paraview] Starting ParaViewWeb from a web application

2013-10-03 Thread Pawel Kwiecien
Hi all, I'm exploring ParaViewWeb included in ParaView 4.0. As described in the documentation (http://www.paraview.org/Wiki/ParaViewWeb), I can run it locally like that ./bin/pvpython lib/site-packages/paraview/web/pv_web_visualizer.py --content www --port 8080 --data-dir $PARAVIEW_DATA My quest