Re: [Paraview] Load state error with MPAS Ocean NetCDFReader data type

2014-02-18 Thread Wolfram, Phillip J
Hi Andy, I have forwarded your email to the list so that the knowledge will be in broader use. Thanks for looking into this so promptly and including the patch. I'm assuming if I recompile via the patch the problem will be solved. Alternatively we could wait until the next binary release

Re: [Paraview] Load state error with MPAS Ocean NetCDFReader data type

2014-02-18 Thread Andy Bauer
Hi Phillip, Yes, if you recompile with the patch it will solve the problem. This fix will make it into ParaView 4.2 (there may be a patch release of 4.1 and I'll see if I can get it into that as well but I can't guarantee that). The Python script would be a potential band-aid for covering

Re: [Paraview] Load state error with MPAS Ocean NetCDFReader data type

2014-02-18 Thread Wolfram, Phillip J
Thanks Andy! Phillip On Feb 18, 2014, at 8:32 AM, Andy Bauer andy.ba...@kitware.commailto:andy.ba...@kitware.com wrote: Hi Phillip, Yes, if you recompile with the patch it will solve the problem. This fix will make it into ParaView 4.2 (there may be a patch release of 4.1 and I'll see if I

[Paraview] Machine Name and Environment - CAVE.pvx

2014-02-18 Thread Léo Pessanha
Hi, I am having a hard time understanding this tags Machine Name and Environment of the cave.pvx file trough the wiki What they are for? When and how do i use then? ___ Powered by www.kitware.com Visit other Kitware open-source projects at

Re: [Paraview] Machine Name and Environment - CAVE.pvx

2014-02-18 Thread Aashish Chaudhary
Machine name identifies the node name in a cluster environment and the Environment is used to specify the Display ID (on linux 0.0, 0.1 etc) that you want to use for a particular viewport. - Aashish On Tue, Feb 18, 2014 at 12:23 PM, Léo Pessanha leonardopessanh...@gmail.com wrote: Hi, I

[Paraview] switch to using the 64 bit headertype for XML writers

2014-02-18 Thread Andy Bauer
Hi, It's been about 18 months since we added the HeaderType option to the XML writers which supports larger data files. When using the UInt64 type for the XML writers it isn't backwards compatible. I was wondering though if it's too early to switch to using the UInt64 header type option in

Re: [Paraview] Machine Name and Environment - CAVE.pvx

2014-02-18 Thread Aashish Chaudhary
Please cc's user's list unless otherwise suggested. On Tue, Feb 18, 2014 at 12:55 PM, Léo Pessanha leonardopessanh...@gmail.com wrote: So i can setup a different Geometry, LowerLeft and etc in each node of a cluster? Yes. The Display ID does not work on windows? I believe you can