Dear All,

I noticed that the Ensight reader encounters problems when running the pvserver 
on more than ~12 processes. Depending on the code which generated the ensight 
file, Paraview either crashes while reading the file or reads the geometry but 
messes up the variable arrays. I carried out test on the standard 
naca.bin.case, which comes with the tutorial data. I noticed that the ensight 
reader already distributes the data over the processes and this might be 
causing the issue. When opening the naca.bin.case with 4, 6, 8 or 10 processes 
I get no errors. If I start the pvserver with 12 processes Paraview hangs while 
reading the file and reports an error:

ERROR: In 
/home/caldron-b/paluszek/linux/Software/Paraview/v5.0.0/ParaView-v5.0.0-source/VTK/Common/DataModel/vtkDataSet.cxx,
 line 435
vtkStructuredGrid (0x1faa690): Point array DENS with 1 components, only has 
-260 tuples but there are 0 points
Strangely it works with 13 parallel processes but I get errors with 14 process 
and again success with 15 ranks and failure with 16.

The second test case was carried out on the disk_out_ref.ex2 converted to 
ensight in Paraview. The ensight writer seems to be having issues on its own as 
is it does not write the *.case file, which is the main ASCII file containing 
metadata. Nevertheless it was easy to generate one based on the naca.bin.case. 
With the converted disk_out_ref I can read the ensight format with up to 12 
parallel processes without any issues. With more ranks I am still able to read 
in the file but the variable arrays become scrambled.

With my other industrial enisght files I get either an error while reading the 
file (log attached) or I read in the files but with scrambled variables. I am 
using Paraview v5.0.0 compiled from source with system libraries. I got the 
same issues with version 4.3 and 4.4 and openmpi, mpich and platform mpi so I 
am assuming that this is not related with my build. Nevertheless, I would 
appreciate if anyone could reproduce this behavior.

Regards,
Lukasz



[Beschreibung: Beschreibung: Description : cid:image001.png@01CF0B8F.DB7831F0]
Łukasz Paluszek
Airbus Helicopters
Aerodynamics Department (ETGA)
86607 Donauwörth
Germany
Tel.: +49 (90) 671 8231
Fax.: +49 (90) 671 9122
lukasz.palus...@airbus.com<mailto:lukasz.palus...@airbus.com>


AIRBUS HELICOPTERS DEUTSCHLAND GmbH

Sitz der Gesellschaft / Registered Office: Donauwörth

Registergericht / Registration Court: Amtsgericht Augsburg HRB 16508

Vorsitzender des Aufsichtsrates / Chairman of the Supervisory Board: Guillaume 
Faury

Geschäftsführung / Board of Management: Dr. Wolfgang Schoder, Vorsitzender / 
CEO; Johannes Kleidorfer; Dr. Klaus Przemeck; Martin Schübel; Stefan Thomé

The information in this e-mail is confidential. The contents may not be 
disclosed or used by anyone other than the addressee. Access to this e-mail by 
anyone else is unauthorised.
If you are not the intended recipient, please notify Airbus immediately and 
delete this e-mail.
Airbus cannot accept any responsibility for the accuracy or completeness of 
this e-mail as it has been sent over public networks. If you have any concerns 
over the content of this message or its Accuracy or Integrity, please contact 
Airbus immediately.
All outgoing e-mails from Airbus are checked using regularly updated virus 
scanning software but you should take whatever measures you deem to be 
appropriate to ensure that this message and any attachments are virus free.

Attachment: log.ensight.crash
Description: log.ensight.crash

_______________________________________________
Powered by www.kitware.com

Visit other Kitware open-source projects at 
http://www.kitware.com/opensource/opensource.html

Please keep messages on-topic and check the ParaView Wiki at: 
http://paraview.org/Wiki/ParaView

Search the list archives at: http://markmail.org/search/?q=ParaView

Follow this link to subscribe/unsubscribe:
http://public.kitware.com/mailman/listinfo/paraview

Reply via email to