Ces VLC writes:
> El El vie, 10 feb 2023 a las 21:44, Barry Smith escribió:
>
>>
>>What is the use case you are looking for that cannot be achieved by
>> just distributing a single precision application? If the user is happy when
>> they happen to have GPUs to use single precision everywhere
El El vie, 10 feb 2023 a las 21:44, Barry Smith escribió:
>
>What is the use case you are looking for that cannot be achieved by
> just distributing a single precision application? If the user is happy when
> they happen to have GPUs to use single precision everywhere, then why would
> they n
What is the use case you are looking for that cannot be achieved by just
distributing a single precision application? If the user is happy when they
happen to have GPUs to use single precision everywhere, then why would they
need double precision if they happen not to have a GPU?
Are y
On Fri, Feb 10, 2023 at 11:31 AM Junchao Zhang
wrote:
>
> On Fri, Feb 10, 2023 at 8:16 AM Ces VLC wrote:
>
>> Hi!
>>
>> I searched if it’s supported to link an application to two different
>> builds of PETSc (one configured as float precision, and the other as
>> double). The last post I found o
On Fri, Feb 10, 2023 at 8:16 AM Ces VLC wrote:
> Hi!
>
> I searched if it’s supported to link an application to two different
> builds of PETSc (one configured as float precision, and the other as
> double). The last post I found on that topic was from 2016 and it said it’s
> not recommended.
>
>
On Fri, Feb 10, 2023 at 9:17 AM 권승리 wrote:
> Dear petsc developers.
>
> Hello.
> While I was applying the preconditioner in contact with the FEM code, I
> had some questions.
>
> How can I apply the AMG PC and the multilevel Schwarz PC in the FEM code?
> Purpose is to compare which PC is better
Dear petsc developers.
Hello.
While I was applying the preconditioner in contact with the FEM code, I had
some questions.
How can I apply the AMG PC and the multilevel Schwarz PC in the FEM code?
Purpose is to compare which PC is better in the FEM code with contact
situation.
In my case, the Jac
Hi!
I searched if it’s supported to link an application to two different builds
of PETSc (one configured as float precision, and the other as double). The
last post I found on that topic was from 2016 and it said it’s not
recommended.
The point is that if you wish to prepare builds of your applic