Em dom., 26 de jan. de 2020 às 23:48, Mark Dilger <
mark.dil...@enterprisedb.com> escreveu:
> > On Jan 24, 2020, at 12:48 PM, Ranier Vilela wrote:
> >
> > 3. At function KeepLogSeg (line 9357) the test if (slotSegNo <= 0), the
> var slotSegNo is uint64 and not can be < 0.
>
> There is something
At Mon, 27 Jan 2020 16:55:56 +0900, Michael Paquier wrote
in
> On Sun, Jan 26, 2020 at 06:47:57PM -0800, Mark Dilger wrote:
> > There is something unusual about comparing a XLogSegNo variable in
> > this way, but it seems to go back to 2014 when the replication slots
> > were introduced in commi
On Sun, Jan 26, 2020 at 06:47:57PM -0800, Mark Dilger wrote:
> There is something unusual about comparing a XLogSegNo variable in
> this way, but it seems to go back to 2014 when the replication slots
> were introduced in commit 858ec11858a914d4c380971985709b6d6b7dd6fc,
> and XLogSegNo was unsigned
> On Jan 24, 2020, at 12:48 PM, Ranier Vilela wrote:
>
> 3. At function KeepLogSeg (line 9357) the test if (slotSegNo <= 0), the var
> slotSegNo is uint64 and not can be < 0.
There is something unusual about comparing a XLogSegNo variable in this way,
but it seems to go back to 2014 when t