Ontario Power Generation user response check prior to use Annual calibration
Ephraim Schwartz > On May 3, 2018, at 2:29 PM, Macho, Michael via Powernet > <powernet@hpspowernet.org> wrote: > > Prior to use source response check for instruments. > > > > Michael Macho > Radiation Protection Staff > michael.ma...@luminant.com > <image001.jpg> > > SAFETY is first > QUALITY > SCHEDULE > Luminant Power > Comanche Peak Nuclear Power Plant > 6322 North FM 56 or PO Box 1002 > Mail Code 005A > Glen Rose, TX 76043 > (254)897-5698 /(254)897-8163 > (817)559-1997 Cell > > From: Powernet [mailto:powernet-boun...@hpspowernet.org] On Behalf Of > Pilgreen Matthew via Powernet > Sent: Thursday, May 03, 2018 12:51 PM > To: 'powernet@hpspowernet.org' <powernet@hpspowernet.org> > Cc: Pilgreen Matthew <mjpilgr...@stpegs.com> > Subject: Re: [Powernet] [EXTERNAL] Re: Portable Radiation Instrument > Performance Checks > > EXTERNAL EMAIL > > South Texas Project’s responses: > > 1. Daily > 2. Technically, it is part of the user checks, but our instrument > tracking software (which we use to log instruments in and out) actually > verifies that the response check has been performed. It will not allow an > individual to check out an instrument that does not have a satisfactory > response check. > > From: Powernet [mailto:powernet-boun...@hpspowernet.org] On Behalf Of John > Ainsley via Powernet > Sent: Thursday, May 03, 2018 12:43 PM > To: powernet@hpspowernet.org > Cc: John Ainsley <john.ains...@dteenergy.com>; BJ Thompson > <bj.thomp...@dominionenergy.com> > Subject: Re: [Powernet] [EXTERNAL] Re: Portable Radiation Instrument > Performance Checks > > **THIS EMAIL IS FROM AN EXTERNAL SENDER OUTSIDE OF THE STPNOC NETWORK. BE > CAUTIOUS ABOUT CLICKING LINKS OR OPENING ATTACHMENTS FROM UNKNOWN SOURCES. DO > NOT PROVIDE PERSONAL INFORMATION SUCH AS SS#, USER ID/PASSWORD, ETC.** > > > Same as DC Cook’s response. > > > Radiation Protection Supervisor – RP Instruments > Fermi-2 Nuclear Power Plant > 734-586-5862 Office > 734-457-1250 Pager > john.ains...@dteenergy.com > <image004.jpg> > PROPRIETARY, CONFIDENTIAL OR PRIVILEGED COMMUNICATION *** > This communication may contain proprietary, privileged or confidential > information protected by law. It is solely for the use of the intended > recipient named above. Any review, dissemination, distribution, forwarding, > or copying of this communication by someone other than the intended > recipient, or the employee responsible for delivering this communication to > the intended recipient, is prohibited. If you have received this > communication in error, please immediately notify the sender via email, then > destroy the original message. > From: Powernet [mailto:powernet-boun...@hpspowernet.org] On Behalf Of Beth > Heyeck via Powernet > Sent: Wednesday, May 02, 2018 2:37 PM > To: 'powernet@hpspowernet.org' <powernet@hpspowernet.org> > Cc: Beth Heyeck <eahey...@aep.com>; BJ Thompson > <bj.thomp...@dominionenergy.com> > Subject: [EXTERNAL] Re: [Powernet] Portable Radiation Instrument Performance > Checks > > DC Cook’s response: > 1. Prior to use/issuance. If it was issued and returned multiple times > in the same shift or day it would receive a check each time it was issued. > 2. It is a documented part of the user’s instrument checks along with a > physical check and a battery check. We document in our instrumentation > program as part of the issuance process. > > Elizabeth Heyeck, CHP > Senior Health Physicist > D.C. Cook Nuclear Plant > 269-466-2545 > eahey...@aep.com > > > From: Powernet [mailto:powernet-boun...@hpspowernet.org] On Behalf Of BJ > Thompson via Powernet > Sent: Wednesday, May 02, 2018 2:29 PM > To: powernet@hpspowernet.org > Cc: BJ Thompson > Subject: [EXTERNAL] [Powernet] Portable Radiation Instrument Performance > Checks > > This is an EXTERNAL email. STOP. THINK before you CLICK links or OPEN > attachments. If suspicious please forward to incide...@aep.com for review. > For plants that perform weekly performance checks for their portable survey > instruments: > > 1. Do you require a daily or prior to use source response check for > instruments? > 2. If you require a daily source response check, is this documented or part > of the user’s instrument checks? > > Thank you for your help! > > > Barbara J. Thompson > North Anna Power Station > 1022 Haley Drive > Mineral, Va 23117 > Superintendent Health Physics Technical Services > bj.thomp...@dominionenergy.com > Phone: 540-894-2638 > > > CONFIDENTIALITY NOTICE: This electronic message contains information which > may be legally confidential and or privileged and does not in any case > represent a firm ENERGY COMMODITY bid or offer relating thereto which binds > the sender without an additional express written confirmation to that effect. > The information is intended solely for the individual or entity named above > and access by anyone else is unauthorized. If you are not the intended > recipient, any disclosure, copying, distribution, or use of the contents of > this information is prohibited and may be unlawful. If you have received this > electronic transmission in error, please reply immediately to the sender that > you have received the message in error, and delete it. Thank you. > > _______________________________________________ > Powernet mailing list > Powernet@hpspowernet.org > http://hpspowernet.org/mailman/listinfo/powernet_hpspowernet.org
_______________________________________________ Powernet mailing list Powernet@hpspowernet.org http://hpspowernet.org/mailman/listinfo/powernet_hpspowernet.org