Re: [Powernet] Quick Initial DLR Issue & DLR Exchange survey

2019-06-26 Thread ROSSER, FREDERICK W via Powernet
Dave, Grand Gulf is the same as ANOs answers. Our last RPM was a fan of admins doing the work, but never got it changed after we got a union in. Fred From: Powernet [mailto:powernet-boun...@hpspowernet.org] On Behalf Of Dave Raye via Powernet Sent: Wednesday, June 26, 2019 11:41 AM To: 'power

Re: [Powernet] surveys following medical exposure to radiopharmaceutical

2019-05-14 Thread ROSSER, FREDERICK W via Powernet
Grand Gulf Nuclear Station 1.Passive monitoring for initial monitoring 2. We use a process to control access to our owner control area called a 'green card' to document the radiopharmaceutical. No survey documentation in the traditional sense (VSDV or RADS) 3. Yes, by name

Re: [Powernet] Quick Hit Benchmark – Area TLD/OSL Monitoring

2019-03-25 Thread ROSSER, FREDERICK W via Powernet
Answers for grand Gulf Nuclear Station: 1. Semi annually. 2. OSL for our area program. Chemistry’s Environmental dosimeters are still TLD, I believe, LiF 3. The number has decreased and will likely go down again due to lower plant staff than when the program was designed.

Re: [Powernet] sending Form 5s and requesting Form 5 using email instead of FAX

2019-03-20 Thread ROSSER, FREDERICK W via Powernet
Grand Gulf does not use email much. We have used it if someone sends a request and asks for it to be emailed, but normal process is it comes in as a fax, we send it back to a fax. I would not be opposed to email though, we would have to set up an account that everyone in dosimetry can access t

Re: [Powernet] Fixed Radiation Monitoring System calibration question

2019-01-28 Thread ROSSER, FREDERICK W via Powernet
At GGNS, I&C performs calibrations of permanently installed plant radiation monitoring systems. Chemistry will assist if needed. RP does escort sources for their use. Fred Rosser RP Specialist 601 437 6571 From: Powernet [mailto:powernet-boun...@hpspowernet.org] On Behalf Of Dave Raye via Po

Re: [Powernet] REMP Sampling Collection

2018-11-15 Thread ROSSER, FREDERICK W via Powernet
At Grand Gulf Nuclear Station, that duty falls to the Chemistry department staff. Fred Rosser HP Specialist Grand Gulf Nuclear Station 7003 Bald Hill Rd. Port Gibson, MS 39150 From: Powernet [mailto:powernet-boun...@hpspowernet.org] On Behalf Of Walters, Jerri via Powernet Sent: Thursday, Nove

Re: [Powernet] SRD settings question

2018-04-17 Thread ROSSER, FREDERICK W via Powernet
Hi Derek, I am the Dosimetry/Instrument Specialist at Grand Gulf Nuclear Station (and in spite of it, an alumni of D. C. Cook) We use the clock function for our electronic dosimeters. We set it for 14 hours. It is only annoying if you take it home or try to keep one for yourself. We have fo