Dave,
Grand Gulf is the same as ANOs answers. Our last RPM was a fan of admins doing
the work, but never got it changed after we got a union in.
Fred
From: Powernet [mailto:powernet-boun...@hpspowernet.org] On Behalf Of Dave Raye
via Powernet
Sent: Wednesday, June 26, 2019 11:41 AM
To: 'power
Grand Gulf Nuclear Station
1.Passive monitoring for initial monitoring
2. We use a process to control access to our owner control area called a
'green card' to document the radiopharmaceutical. No survey documentation in
the traditional sense (VSDV or RADS)
3. Yes, by name
Answers for grand Gulf Nuclear Station:
1. Semi annually.
2. OSL for our area program. Chemistry’s Environmental dosimeters are
still TLD, I believe, LiF
3. The number has decreased and will likely go down again due to lower
plant staff than when the program was designed.
Grand Gulf does not use email much. We have used it if someone sends a request
and asks for it to be emailed, but normal process is it comes in as a fax, we
send it back to a fax. I would not be opposed to email though, we would have
to set up an account that everyone in dosimetry can access t
At GGNS, I&C performs calibrations of permanently installed plant radiation
monitoring systems. Chemistry will assist if needed. RP does escort sources
for their use.
Fred Rosser
RP Specialist
601 437 6571
From: Powernet [mailto:powernet-boun...@hpspowernet.org] On Behalf Of Dave Raye
via Po
At Grand Gulf Nuclear Station, that duty falls to the Chemistry department
staff.
Fred Rosser
HP Specialist
Grand Gulf Nuclear Station
7003 Bald Hill Rd.
Port Gibson, MS 39150
From: Powernet [mailto:powernet-boun...@hpspowernet.org] On Behalf Of Walters,
Jerri via Powernet
Sent: Thursday, Nove
Hi Derek,
I am the Dosimetry/Instrument Specialist at Grand Gulf Nuclear Station (and in
spite of it, an alumni of D. C. Cook) We use the clock function for our
electronic dosimeters. We set it for 14 hours. It is only annoying if you
take it home or try to keep one for yourself. We have fo