Comanche Peak is the same. 365 days

Michael Macho
Radiation Protection Staff
michael.ma...@luminant.com
[cid:image001.jpg@01D2E388.D05BF2F0]

SAFETY is first
QUALITY
SCHEDULE
Luminant Power
Comanche Peak Nuclear Power Plant
6322 North FM 56 or PO Box 1002
Mail Code 005A
Glen Rose, TX  76043
(254)897-5698 /(254)897-8163
(817)559-1997 Cell

From: Johnson, Graham Thomas [mailto:graham.john...@duke-energy.com]
Sent: Monday, June 12, 2017 2:14 PM
To: powernet@HPSpowernet.org
Subject: [powernet] FW: Powernet question on emergency kit survey instrument 
calibration grace periods

EXTERNAL EMAIL


Duke Energy response:

From: Schlise, Larry Dale
Sent: Monday, June 12, 2017 3:08 PM
To: miwil...@southernco.com<mailto:miwil...@southernco.com>
Cc: Johnson, Graham Thomas; Faulkenberry, Bill; Pell, Bryan Scott
Subject: Powernet question on emergency kit survey instrument calibration grace 
periods

All six Duke Energy nuclear sites use a maximum of 365 days for the calibration 
frequency for the emergency kit survey instruments.  We have no grace period 
for any of our RP radiation or contamination monitors.

Larry Schlise
Senior  Scientist, EnRad Labs
Duke Energy
[EnRad Logo.jpg]
13339 Hagers Ferry Rd
Mail Stop MG03A2
Huntersville, NC  28078
980-875-5395 (Office)
704-787-3401 (Mobile)

Reply via email to