]but not yet an official
information.
Exporters return the current data when polled, so don't store anything
themselves.
The data is persisted within the Prometheus TSDB once scraped.
--
Stuart Clark
--
You received this message because you are subscribed to the Google Groups
"Prometheus
at the linear prediction & derivative
functions. For example alerting on disk due to run out within 4 hours,
or a response time SLA due to be breached within 2 hours.
On Thursday, February 20, 2020 at 4:03:18 PM UTC+5:30, Stuart Clark
wrote:
As long as there are some metrics which
If you have more than one copy of Prometheus running against the same data
directory you will cause corruption.
They need to be using separate directories and the use of NFS is generally not
recommended.
On 20 February 2020 12:40:59 GMT, Guru SD wrote:
>Yes we have two Prometheus servers
anyone to
be able to see & query your metrics system you'd probably want to look
at whitelisting, TLS & authentication.
On Thursday, 20 February 2020 10:35:33 UTC, Stuart Clark wrote:
That sounds like an AWS thing. However it is generally advisable to
run Prometheus servers within each
That sounds like an AWS thing. However it is generally advisable to run
Prometheus servers within each failure domain and not scrape things across
domains. So for this I'd suggest a Prometheus server in each region.
On 20 February 2020 10:18:00 GMT, Ollie Sutton wrote:
>I am having this issue
As long as there are some metrics which give a good indication that things are
about to break then yes.
For example you can alert on 100% disk usage, but you can also alert on disk
usage projected to reach 100% within the next hour
On 20 February 2020 10:26:05 GMT, Isabel Noronha
wrote:
>I
Maybe you could use the blackbox exporter to monitor the service as well as
response times?
On 20 February 2020 07:34:27 GMT, Srinivasa Reddy B
wrote:
>Hi am srinivasa am installed prometheus in my EKS cluster using Helm
>charts
>currently its running fine But my Project manager asking to do
miss the second, Is there
any way in prometheus to accomplish this ?
The maximum scrape rate for Prometheus is about 2 minutes due to
staleness.
Can you switch to say scraping every minute?
Regards,
Arun Raj. R
On Sunday, February 16, 2020 at 11:53:54 PM UTC+9, Stuart Clark wrote:
Both
Both are expected.
The scrape interval is an average, so gaps between scrapes might be a bit
longer or shorter each time. Different scrapes with the same scrape interval
will happen at different times to prevent everything happening at once,
overwhelming the server and network.
Ideally most
501 - 509 of 509 matches
Mail list logo