From: BALATON Zoltan <bala...@eik.bme.hu> In ppc6xx_tlb_pte_check() the pp variable is used only once to pass it to a function parameter with the same name. Remove the local and inline the value. Also use named constant for the hex value to make it clearer.
Signed-off-by: BALATON Zoltan <bala...@eik.bme.hu> Reviewed-by: Nicholas Piggin <npig...@gmail.com> Signed-off-by: Nicholas Piggin <npig...@gmail.com> --- target/ppc/mmu_common.c | 5 ++--- 1 file changed, 2 insertions(+), 3 deletions(-) diff --git a/target/ppc/mmu_common.c b/target/ppc/mmu_common.c index b21f52290f..799d2ced9b 100644 --- a/target/ppc/mmu_common.c +++ b/target/ppc/mmu_common.c @@ -98,13 +98,12 @@ static int ppc6xx_tlb_pte_check(mmu_ctx_t *ctx, target_ulong pte0, target_ulong pte1, int pteh, MMUAccessType access_type) { - int ret, pp; + int ret; ret = -1; /* Check validity and table match */ if (pte_is_valid(pte0) && ((pte0 >> 6) & 1) == pteh) { /* Check vsid & api */ - pp = pte1 & 0x00000003; if ((pte0 & PTE_PTEM_MASK) == ctx->ptem) { if (ctx->raddr != (hwaddr)-1ULL) { /* all matches should have equal RPN, WIMG & PP */ @@ -115,7 +114,7 @@ static int ppc6xx_tlb_pte_check(mmu_ctx_t *ctx, target_ulong pte0, } /* Keep the matching PTE information */ ctx->raddr = pte1; - ctx->prot = ppc_hash32_prot(ctx->key, pp, ctx->nx); + ctx->prot = ppc_hash32_prot(ctx->key, pte1 & HPTE32_R_PP, ctx->nx); if (check_prot_access_type(ctx->prot, access_type)) { /* Access granted */ qemu_log_mask(CPU_LOG_MMU, "PTE access granted !\n"); -- 2.45.2