On 22 November 2011 03:25, Peter Chubb peter.ch...@nicta.com.au wrote:
Properly implement dual-timer read/write for the sp804 dual timer module.
Based on ARM specs at
http://infocenter.arm.com/help/index.jsp?topic=/com.arm.doc.ddi0271d/index.html
Signed-off-by: Hans Jang hsj...@ok-labs.com
Hi Peter,
Here's a fixed patch for the sp804 timer.
Properly implement the dual-timer read/write for the sp804 dual timer module.
Based on ARM specs at
http://infocenter.arm.com/help/index.jsp?topic=/com.arm.doc.ddi0271d/index.html
Signed-off-by: Peter Chubb peter.ch...@nicta.com.au
Am 21.11.2011 23:05, schrieb Peter Chubb:
Hi Peter,
Here's a fixed patch for the sp804 timer.
Properly implement the dual-timer read/write for the sp804 dual timer module.
Based on ARM specs at
http://infocenter.arm.com/help/index.jsp?topic=/com.arm.doc.ddi0271d/index.html
Properly implement dual-timer read/write for the sp804 dual timer module.
Based on ARM specs at
http://infocenter.arm.com/help/index.jsp?topic=/com.arm.doc.ddi0271d/index.html
Signed-off-by: Hans Jang hsj...@ok-labs.com
Signed-off-by: David Mirabito david.mirab...@nicta.com.au
Signed-off-by:
On 30 September 2011 01:20, Peter Chubb peter.ch...@nicta.com.au wrote:
Thanks Peter!
Here's a reworked patch.
NB: when you resend patches it's better to send them as completely
fresh emails (via git-send-email or equivalent) because otherwise they're
more of a pain to apply (you end up with
Peter == Peter Maydell peter.mayd...@linaro.org writes:
Peter On 30 September 2011 01:20, Peter Chubb
Peter peter.ch...@nicta.com.au wrote:
Thanks Peter!
Here's a reworked patch.
Peter NB: when you resend patches it's better to send them as
Peter completely fresh emails (via git-send-email
On 30 September 2011 10:23, Peter Chubb peter.ch...@nicta.com.au wrote:
Peter == Peter Maydell peter.mayd...@linaro.org writes:
Peter hw_error() is a fatal error -- don't use it for conditions that
Peter can be triggered by a malicious guest. (And since it's noreturn
Peter there's not much
On 29 September 2011 03:34, Peter Chubb peter.ch...@nicta.com.au wrote:
-/* ??? Don't know the PrimeCell ID for this device. */
if (offset 0x20) {
return arm_timer_read(s-timer[0], offset);
-} else {
+}
+if (offset 0x40) {
return
Thanks Peter!
Here's a reworked patch.
From 7af8e24d6cbd9170a206b6aaac164e3934312b7c Mon Sep 17 00:00:00 2001
From: David Mirabito david.mirab...@nicta.com.au
Date: Fri, 24 Jul 2009 11:43:14 +1000
Subject: [PATCH 53/57] Fix sp804 read/write for second timer.
Properly implement the dual-timer
This patch was written by David Mirabito.
Properly implement the dual-timer read/write for the sp804 dual timer module.
Based on ARM specs at
http://infocenter.arm.com/help/index.jsp?topic=/com.arm.doc.ddi0271d/index.html
Signed-off-by: Peter Chubb peter.ch...@nicta.com.au
Signed-off-by: David
10 matches