Re: [ntp:questions] How common is LI=3 - solved.

2017-02-05 Thread David Woolley
On 05/02/17 00:22, Robert Scott wrote: I hope to achieve a frequency accuracy of 5 PPM. Once that measurement is made, I store it for subsequent use in my app. The equipment doesn't have a very long service life and is in a temperature controlled environment, as I think both ageing and therm

Re: [ntp:questions] How common is LI=3 - solved.

2017-02-05 Thread Brian Inglis
On 2017-02-05 02:14, David Woolley wrote: > On 05/02/17 00:22, Robert Scott wrote: >> I hope to achieve a frequency accuracy of 5 PPM. Once that >> measurement is made, I store it for subsequent use in my app. > The equipment doesn't have a very long service life and is in a > temperature controlle

Re: [ntp:questions] How common is LI=3 - solved.

2017-02-05 Thread William Unruh
On 2017-02-05, David Woolley wrote: > On 05/02/17 00:22, Robert Scott wrote: >> I hope to achieve a >> frequency accuracy of 5 PPM. Once that measurement is made, I store >> it for subsequent use in my app. 5ppm is not hard if you keep discipling the clock with ntpd/chrony. If you let it freeru