(RADIATOR) Re: Problem about Time check item

2001-06-22 Thread chairarth
Hi Hugh, I have done following your suggestion and I found that I can control Times of Day which user is allowed to log on. But I 've got a problem about RADUSERS and RADUSAGE Table. In log file you can see that after user test2@qnetadsl log out , Radiator then din't do query update RADUSERS

Re: (RADIATOR) Dual accounting

2001-06-22 Thread Hugh Irvine
Title: Re: (RADIATOR) Dual accounting Hello Chris - At 2:01 PM -0700 6/21/01, Chris Sellers wrote: I am running Radiator on BSDI4.1. I have the accounting logging to a file via AcctLogFileName in the cfg. We use a billmax billing system that needs this information sent to it, to be added to

Re: (RADIATOR) Digest::MD4 on RedHat???

2001-06-22 Thread Hugh Irvine
Hello Carl - You will find MD4 on CPAN (www.cpan.org). http://www.cpan.org/modules/by-module/Digest/Digest-MD4-1.0.tar.gz regards Hugh At 6:42 PM -0400 6/21/01, Carl Litt wrote: I am having a problem with Radiator 2.18.2 dying after receiving MS-CHAP autentication requests. Perl complains

Re: (RADIATOR) Attribute Length

2001-06-22 Thread Hugh Irvine
Title: Re: (RADIATOR) Attribute Length Hello Brandon - You can do both these things in a PostAuthHook. There are some examples in the file goodies/hooks.txt. hth Hugh At 1:54 AM -0700 6/21/01, Brandon wrote: Ive had a request to reduce attribute 242 (Ascend Data Filter) from 28 to 26

Re: (RADIATOR) PostAuthHook question.

2001-06-22 Thread Hugh Irvine
Hello Griff - At 9:33 AM -0700 6/21/01, Griff Hamlin wrote: Hello, I'm in need of adding specific attributes to the reply packets for one of the routers I have to authenticate (out of hundreds). Since I only have need for one handler and we don't use realms, I figure the best thing to do would

Re: (RADIATOR) Telco invoice does not match the monthly sessionsdura tion

2001-06-22 Thread Hugh Irvine
Hello Slavka - At 10:07 AM +0200 6/22/01, Slavka Trifonova wrote: Hello all, I have a problem with reconciling dial-in usage reported by telco and accounted by Radiator. The sessions duration (radiator accounting) seems to be approximately +5% longer than the telephone calls duration for a

(RADIATOR) Re: Problem about Time check item

2001-06-22 Thread Hugh Irvine
Title: Re: Problem about Time check item Hello Chairarth - Quite right - my fault, I'm sorry. Try setting up your Handlers like this (no Realms): # handle accounting requests seperately Handler Request-Type = Accounting-Request AuthBy RADMINAUTH /Handler Handler Realm = qnetadsl

(RADIATOR) Re:

2001-06-22 Thread Hugh Irvine
Hello Asi - hello I buy the radiator in 20.06.2001 I need to know if I can put the = radiator as a service in the server and how I can do so I need to put the radiator as a service Please have a look at section 16 (16.4 for NT) in the Radiator 2.18.2 reference manual (doc/ref.html in the

(RADIATOR) A problem with socket read queue length

2001-06-22 Thread enrique . carnicero
Hello, When I start radiator I con find this message in the log file: Fri Jun 22 10:22:09 2001: WARNING: Could not set socket read queue length for accounting to 25: Bad file number Does anybody what it means? How can I avoid this message? My radiator is installed on a Sun machine with

(RADIATOR) Authentication Thru Radiator with system passwd file

2001-06-22 Thread Mike McCauley
--- Forwarded mail from [EMAIL PROTECTED] From: [EMAIL PROTECTED] Date: Fri, 22 Jun 2001 04:27:30 -0500 To: [EMAIL PROTECTED] Subject: BOUNCE [EMAIL PROTECTED]:Non-member submission from [Javaid Sajjad [EMAIL PROTECTED]] From [EMAIL PROTECTED] Fri Jun 22 04:27:29 2001 Received: from

Re: (RADIATOR) A problem with socket read queue length

2001-06-22 Thread Hugh Irvine
Hello Enrique - The only way you can change this in Radiator is with the SocketQueueLength parameter, so you should just remove this line from the configutation file. regards Hugh At 1:23 PM +0200 6/22/01, [EMAIL PROTECTED] wrote: Hello, When I start radiator I con find this message in

Re: (RADIATOR) Authentication Thru Radiator with system passwdfile

2001-06-22 Thread Hugh Irvine
Hello Javaid - Hello ! Would you plese let me know how to configure Radiator's radius.cfg file for authentication through Linux default passwd file ie /etc/passwd which is in our case is flat one not shadow.Further more we want to authenticate from Livingston Access Server throu Radiator

Re: (RADIATOR) Authentication Thru Radiator with system passwdfile

2001-06-22 Thread Hugh Irvine
Hello Javaid - If you send me a copy of your configuration file (no secrets) together with a trace 4 debug from Radiator, I will take a look. regards Hugh At 7:10 PM +0500 6/22/01, [EMAIL PROTECTED] wrote: Hi, Thanx for that suggestion but it is not working- i think something should be

(RADIATOR) Feature Request

2001-06-22 Thread Chris Given
Im not sure how radiator internally works, but I was wondering if it would be possible to send a batch of all the current authentication requests waiting up to a database server (Using XML) and return a result set of there attributes. Something like this Auth Query : EXEC

Re: (RADIATOR) Feature Request

2001-06-22 Thread Hugh Irvine
Hello Chris - Radiator is single-threaded, so it only ever handles a single request. regards Hugh At 8:37 AM -0600 6/22/01, Chris Given wrote: Im not sure how radiator internally works, but I was wondering if it would be possible to send a batch of all the current authentication requests

Re: (RADIATOR) Attribute Length

2001-06-22 Thread Brandon
Title: Re: (RADIATOR) Attribute Length I checked there but didn't find an example that I could use. Im worried that if I do a: $rp-delete_attr('Proxy-State'); That it will strip all the proxy-state attributes and not just the one sent by the last pass through customer. And also, I saw

Re: (RADIATOR) Authentication Thru Radiator with system passwd file

2001-06-22 Thread Mike McCauley
--- Forwarded mail from [EMAIL PROTECTED] From: [EMAIL PROTECTED] Date: Fri, 22 Jun 2001 07:13:41 -0500 To: [EMAIL PROTECTED] Subject: BOUNCE [EMAIL PROTECTED]:Non-member submission from [[EMAIL PROTECTED]] From [EMAIL PROTECTED] Fri Jun 22 07:13:41 2001 Received: from

(RADIATOR) Need help urgently

2001-06-22 Thread Mohammed AbdusSami
Dear All, In my configuration radiator is passing the parameter framed-ip-netmask as 255.255.255.0 but when I connect thru dialup it is taking 255.255.0.0 Can anybody help me to fix this problem. Regards, AbdusSami === Archive at http://www.open.com.au/archives/radiator/ Announcements on