Hi, all.
I get this:
ERR: Could not connect to SQL database with DBI-conne
ct dbi:mysql:radmin:localhost, root, PASSWORD: Can't connect to local MySQL ser
ver through socket '/var/lib/mysql/mysql.sock' (111)
ERR: Could not connect to any SQL database. Request is ignored. Backing off for 600
Hello Miguel and all other.
MALP ERR: Could not connect to SQL database with DBI-conne
MALP ct dbi:mysql:radmin:localhost, root, PASSWORD: Can't connect to local MySQL ser
MALP ver through socket '/var/lib/mysql/mysql.sock' (111)
MALP ERR: Could not connect to any SQL database. Request is
Hello Miguel -
What version of Radiator are you running? What version of Perl? What version
of DBI/DBD? What hardware/software platform? And when does the problem occur?
Could you also provide a copy of your configuration file (no secrets)
together with a trace 4 debug from Radiator showing
Hello !
On Thursday 02 August 2001 15:59 pm, Pavel A Crasotin wrote:
does anybody know what is the attribute 28, vendor 529
(Ascend)?
It appeared in the logfile right after I've upgraded TAOS on MAX6000.
Digging ftp://ftp.ascend.com, http://www.lucent.com, etc does not give a
results.
Im looking for Vendor (Ascend, code 529) Specific Attribiute 28 not for RFC2865.
AAS Hello !
AAS On Thursday 02 August 2001 15:59 pm, Pavel A Crasotin wrote:
does anybody know what is the attribute 28, vendor 529
(Ascend)?
It appeared in the logfile right after I've upgraded TAOS on
Hello Tom -
Note that the correct spelling is Filter-Id in your user definitions.
You will have to check a trace 4 debug from Radiator to verify that the
correct attribute is being sent back to the NAS, then you will have to check
on the NAS that it is dealing with the filter correctly.
hth
We run Platypus and Radiator on an NT4 box. Two weeks ago we upgraded the
Hardware and reinstalled the software on a Dual processor machine with 1GB
memory and RAID 1,0 and it goes but.. radiator now stops after about 2
or 3 days. Only a restart (This is NT) with get it going again. Platypus
Hi Hugh,
Me and my darn typing fingers...you're right. Filter-Id!
Thanks as always,
Tom
- Original Message -
From: Hugh Irvine [EMAIL PROTECTED]
To: Tom Daly [EMAIL PROTECTED]; [EMAIL PROTECTED]
Sent: Monday, August 06, 2001 6:42 AM
Subject: Re: (RADIATOR) Filters
Hello Tom -
Note
unsubscribe
===
Archive at http://www.open.com.au/archives/radiator/
Announcements on [EMAIL PROTECTED]
To unsubscribe, email '[EMAIL PROTECTED]' with
'unsubscribe radiator' in the body of the message.
Hi Mike, Hugh...
it's been more than a couple of months since this message... in fact, the
Log.pm got into 2.18.2 in the meantime... the problem I have is that I still
couldn't solve my first item:
1) As I noted in a message exchange with Hugh (cc: the list) a couple of
weeks ago, AuthLog
Hello Mark -
Have you upgraded to the latest version of ActivePerl?
www.activestate.com
Looks like perl 5.6.1 is the latest.
To say any more we would have to see a copy of the configuration file (no
secrets), together with a trace 4 debug showing what happens when Radiator
stops.
Hello Chairarth -
On Tuesday 07 August 2001 15:17, Chairarth K wrote:
Hi ,
By now , we implement Radiator 2.18.2 and Radmin 1.4 on Windows NT. So
my question is how can I config radiator to doen't send any log message
to RADMESSAGES table at MS-SQL server.
You can just specify an empty
12 matches
Mail list logo