Hi,
I'm currently evaluating Radiator to replace our current IAS Radius.
We have a Cisco PIX which will be doing aaa against IAS & MS Active Directory, for all
HTTP requests from the INSIDE network to the Internet.
I have manage to authenticate with a very basic configuration:
Foreground
LogSt
Hello Peter -
Yes you should set up an SQL session database, for which you will find
details in section 6.7 of the Radiator reference manual ("doc/ref.html").
You will then be able to use the "radwho.cgi" script to view the online users.
regards
Hugh
On Thu, 10 Jan 2002 17:13, Peter Zhu wr
Hello ,
I have installed radiator radius, we use database interbase to
authenticate users.
I want to check current users which connected to us, I am wandering if
we need to use:SessionDatabase SQL or not.
If yes, would you tell me how to set up the configuration file.
thanks ,
peter zhu from u
Hello Quintin -
>
> Dear Sir,
>
> Can Radiator run in Solaris8 X86 platform?
>
Yes, provided you have Perl and a suitable C compiler. You can find both at
www.sunfreeware.com.
regards
Hugh
--
Radiator: the most portable, flexible and configurable RADIUS server
anywhere. Available on *NIX,
-- Forwarded Message --
Subject: BOUNCE [EMAIL PROTECTED]:Non-member submission from
["Quintin" <[EMAIL PROTECTED]>]
Date: Wed, 9 Jan 2002 17:58:33 -0600
From: [EMAIL PROTECTED]
To: [EMAIL PROTECTED]
>From [EMAIL PROTECTED] Wed Jan 9 17:58:33 2002
Received: from ctmsun4
Hello Michael -
A copy of the snmpwalk would be useful. I will also need to know the
Portmaster model number and the firmware/software version.
thanks
Hugh
On Wed, 9 Jan 2002 10:59, Michael Bellears wrote:
> Replacing the Nas.pm does not seem to fix the snmp problem to the PM3
> (See debug
Hello Doug -
>
> Hi Broadwing has started requiring the following info passwd back to
> them.
>
> > Ascend-Data-Filter = "ip in forward tcp est",
> > Ascend-Data-Filter = "ip in forward dstip 192.48.96.0/24",
> > Ascend-Data-Filter = "ip in drop tcp dstport = 25",
> > Ascend-Data-Filter = "ip in
Hello Eapen -
The problem you have is due to several things.
First of all, your configuration file should be changed slightly to deal with
possibly missing attributes that are used in the calculation refered to in
the error message.
This part of the SQL statement should be changed:
Hello Craig -
>
> Currently, we are doing some accounting updates to our MySQL database
> using the following code in RADIUS.CFG:
>
> AcctSQLStatement update SUBSCRIBERS set TIMELEFT=TIMELEFT-0%{Acct-
> Session-Time} where USERNAME='%n'
>
> So if a user has a session-time of 50 seconds, they are
Hello Wasim -
You should use the "Time " check item as described in section 13.1.13 of
the Radiator 2.19 reference manual ("doc/ref.html").
regards
Hugh
On Wed, 9 Jan 2002 21:16, Wasim Ahmed Khan wrote:
> Hi
> i have user in database which status is like he can connect from 10am
> to 9
Hello Jesus -
As the AuthBy RADIUS clause operates asynchronously, you can only call a
following AuthBy clause using a ReplyHook. There is an example of how to do
this in the file "goodies/hooks.txt" in the Radiator 2.19 distribution.
regards
Hugh
On Thu, 10 Jan 2002 02:48, Jesús M Díaz wr
Hello Simon -
You are correct - it is not possible to do this with radius.
regards
Hugh
On Thu, 10 Jan 2002 10:33, Simon Pope wrote:
> Can you get a user authenticating against our Radius server via the NT SAM
> to change thier password as part of the authentication process if it has
> expir
Hello Lewis -
I will need to see a copy of your configuration file (no secrets) together
with a trace 4 debug showing what is happening.
thanks
Hugh
On Thu, 10 Jan 2002 10:17, Lewis Gorley wrote:
> hi
> how can radius from letting long on more then once ? the error message I
> get is below
Title: Message
Lewis :)
This
is done thru the statement...
defaultsimultaneoususe 1 inside the GROUPBY clauses or
AUTHBY.
Cheers!
Saludos
Anton KrallDirector de
TecnologíaInter.net
México / Panamá
Tel; 5241-7609
Directo
Tel: 5241-7600
Conmutador
Celular:
0445-105-5160 Mobi
Hello William -
I am not quite sure what you mean - can you send me a trace 4 showing what is
contained in the packets?
thanks
Hugh
On Thu, 10 Jan 2002 06:30, William Hernandez wrote:
> Hello everyone,
>
> I found the following messages in the Radiator Archive and it appears to
> be basica
Hello Danny -
You can improve the IP address allocation performance in MySQL by adding a
"limit 1" to the FindQuery as described in section 6.51.5 in the Radiator
2.19 reference manual.
regards
Hugh
On Thu, 10 Jan 2002 06:06, [EMAIL PROTECTED] wrote:
> Hi,
>
> We've been having trouble wit
Hello Nick -
This is fairly standard for most NAS(s) so you should try it and see what
happens. Otherwise you should check the CVX documentation.
regards
Hugh
On Thu, 10 Jan 2002 07:24, Nick Rogness wrote:
> I come from a Livingston world where sending an attribute of:
>
> Framed-IP-A
Can you get a user authenticating against our Radius server via the NT SAM
to change thier password as part of the authentication process if it has
expired? I suspect you can't but I'm just after a sanity check. Thanks in
advance.
_
hi
how can radius from letting long on more then
once ? the error message I get is below:
Wed Jan 9 18:14:13 2002: INFO: Access
rejected for [EMAIL PROTECTED]:
Simultaneous-Use of 1 exceeded
-- Forwarded Message --
Subject: BOUNCE [EMAIL PROTECTED]:Non-member submission from ["Eapen
Joseph" <[EMAIL PROTECTED]>]
Date: Wed, 9 Jan 2002 13:59:44 -0600
From: [EMAIL PROTECTED]
To: [EMAIL PROTECTED]
>From [EMAIL PROTECTED] Wed Jan 9 13:59:44 2002
Received: from ma
-- Forwarded Message --
Subject: BOUNCE [EMAIL PROTECTED]:Non-member submission from ["Doug
Currey" <[EMAIL PROTECTED]>]
Date: Wed, 9 Jan 2002 13:57:41 -0600
From: [EMAIL PROTECTED]
To: [EMAIL PROTECTED]
>From [EMAIL PROTECTED] Wed Jan 9 13:57:41 2002
Received: from its
-- Forwarded Message --
Subject: BOUNCE [EMAIL PROTECTED]:Non-member submission from ["C
Thompson" <[EMAIL PROTECTED]>]
Date: Wed, 9 Jan 2002 08:58:45 -0600
From: [EMAIL PROTECTED]
To: [EMAIL PROTECTED]
>From [EMAIL PROTECTED] Wed Jan 9 08:58:44 2002
Received: from agap
Hi,
We've been having trouble with postgresql as our database for radiator/radmin. So
we've decided to switch to mysql. I'm wondering if there are some mysql guru's out
there who can give me some good tips to optimize the database tables. We've set up
indexes on all the tables/columns that are
I come from a Livingston world where sending an attribute of:
Framed-IP-Address = 255.255.255.254,
Told the portmaster to choose an IP from its Address pool for the
Framed-IP. How is this done using a users file for the CVX?
Nick Rogness <[EMAIL PROTECTED]>
- Don't mind me...I'm just
Hello everyone,
I found the following messages in the Radiator Archive and it appears to
be basically the same situation that I'm encountering.
We're running Radiator 2.18.2 and we proxy requests for a specific realm
to another radius server. And the detail file has multiple timestamps in
the sa
Hello,
may i put an 'AuthBy xxx' clause after an 'AuthBy RADIUS' one?
i am trying to do that, but it seems not to processing it, is that correct?
thank you.
jm
--
Jesus M Diaz <[EMAIL PROTECTED]>
ONO
Planificación y Diseño de Red SAE
Tfno: +34 91 180 9109
Fax: +34 91 180 9245
===
Archi
Hi
i have user in database which status is like he can connect from 10am
to 9pm but not after 9pm or before 10am i have done my database work
but is there anyway by which i can haddel it through radiator
Regards,
Wasim Ahmed Khan.