On 05/12/2014 02:22 PM, a.l.m.bu...@lboro.ac.uk wrote:
Status-Server based failure detection needs two options specified in
AuthBy RADIUS or Host within AuthBy RADIUS:
- Flag: UseStatusServerForFailureDetect
- Integer: KeepaliveTimeout numsec
what is the interplay/interaction with RADSEC
Hi,
Status-Server based failure detection needs two options specified in
AuthBy RADIUS or Host within AuthBy RADIUS:
- Flag: UseStatusServerForFailureDetect
- Integer: KeepaliveTimeout numsec
what is the interplay/interaction with RADSEC for this StatusServer method?
cheers
alan
On 06/19/2013 10:35 AM, Heikki Vatiainen wrote:
The patch set for Radiator 4.11 now has changes to make Status-Server
based detection of failed Hosts more reliable especially when there is
more than one Host defined for AuthBy RADIUS or its subclasses.
These changes are now available for
The patch set for Radiator 4.11 now has changes to make Status-Server
based detection of failed Hosts more reliable especially when there is
more than one Host defined for AuthBy RADIUS or its subclasses.
Using Status-Server for active probing is an alternative of using the
lack of responses for