Re: [RE-wrenches] ground mounted systems

2014-08-08 Thread Solar
I saw a couple US Solar Mounts at the energy fair in WI this summer. I really liked their setup. I forgot about them. They do have wire management. Jesse Sent from my iPhone > On Aug 8, 2014, at 6:48 PM, "RE Ellison" wrote: > > Look into US Solar Mounts, Eric has built in wire management an

Re: [RE-wrenches] ground mounted systems

2014-08-08 Thread RE Ellison
Look into US Solar Mounts, Eric has built in wire management and some real nice looking racks. I have been watching make constant improvements every year for quite a while. Before his racks I thought DPW was the best we could get, These look tougher and the wire management is real slick. Lo

Re: [RE-wrenches] ground mounted systems

2014-08-08 Thread Solar
William Miller has some nice ideas on his website regarding protecting circuits. I've used his ideas on one project and the inspector liked it. Silicon Energy makes a module with raceways for output circuits. Their module is expensive comparatively speaking and I've never seen one of their 190W

Re: [RE-wrenches] ground mounted systems

2014-08-08 Thread Robert Evans
I have been using this product: www.solarscrim.com Its inexpensive, easy to install, and the inspectors in Santa Cruz county like it. I use the under array version just to cover the conductors. Bob Evans Evans Energy Systems Santa Cruz, CA 831-345-3459 On Aug 8, 2014 2:50 PM, wrote: > GROUND M

[RE-wrenches] Aloha!

2014-08-08 Thread James Rudolph
Does anybody have any experience with Silvero panels. we may be getting a container full these and I was looking for some feedback. Mahalo, *James B. Rudolph* *Haleakala Solar* *Director of Construction* *NABCEP Certified PV Installer # 091209-155*

[RE-wrenches] ground mounted systems

2014-08-08 Thread tom
GROUND MOUNTED SYSTEMS NEC 690.31 REQUIRING FENCING OR SOMETHING TO PREVENT THE VILLAGE IDIOT FROM PLAYING WITH THE PV source and output conductor circuits . Besides fencing what raceways or guarding passes code and what manufacturers have a raceway , etc . to provide physical protection and reduce

Re: [RE-wrenches] WorkTruck Inverter Suggestions

2014-08-08 Thread Larry Crutcher, Starlight Solar Power Systems
Hi Bill, I’m probably stating the obvious but we always install mobile inverters closest to the battery due to the high loss at 12 volts, then run AC to the point of use. Larry On Aug 7, 2014, at 7:07 AM, Bill Loesch wrote: Gentlemen: Does anyone have any suggestions/preferences on mounti