Re: [RE-wrenches] B3 Bypass breaker

2018-02-21 Thread Howard Arey
I just tried calling because anything that helps me on 120% challenges is a top priority with me. Just got a voice recorder with no identification and elevator music…I suspect the cheesy video at the website with people swimming in the ocean but no view of the installed product never helped

Re: [RE-wrenches] Li+ Systems Puerto Rico

2018-02-21 Thread Darryl Thayer
Jerry, can we see the egauge results? On Tue, Feb 20, 2018 at 11:59 PM, Jerry Shafer wrote: > Wrenches > We have been doing testing on the Blue Ion over the last several months, > we have been using PV, back up grid connected charger, we have CT's on DC > in, PV in, Charger in, and Load out, som

Re: [RE-wrenches] B3 Bypass breaker

2018-02-21 Thread Jerry Shafer
We tried several times but they (B3) were never able to produce, are they available yet, l saw them at SPI Dallas years back. Jerry On Feb 21, 2018 6:37 AM, "Dana" wrote: > Has anyone used the B3 buss-bar bypass breaker setup yet? www.qfe002.com > > Were there any permitting issues? > > I am run

[RE-wrenches] B3 Bypass breaker

2018-02-21 Thread Dana
Has anyone used the B3 buss-bar bypass breaker setup yet? www.qfe002.com Were there any permitting issues? I am running the tech sheet & compliance pages by our permitting examiners here in Idaho.