Nope, but I can't get in either.
On June 3, 2024 6:42:25 AM John Blittersdorf via RE-wrenches wrote:
Seems Optics is off line again. Anyone have news?
John Blittersdorf
NABCEP Certified Solar PV Installation Professional™
CV Wind Service (and solar)
200 West Road
N Chittenden, VT 05763
"OPTICS RE Back Online
Report
Quote
Post by Marshall Neipert » 20 May 2024 20:32
Enersys has fixed the issue and Optics RE is back online."
Except it is not for me.ToddOn Tuesday, May 21, 2024 7:22am, "Dave Angelini Offgrid Solar via RE-wrenches" said:
Anyone who fixes Outback's inability
Mine is down too as well as through the back door:
[ https://23.99.68.42/Home/#/system/dashboard ](
https://23.99.68.42/Home/#/system/dashboard )
Todd
On Saturday, May 18, 2024 9:23am, "John Blittersdorf via RE-wrenches"
said:
Mine are down also since 2pm EDT yesterday
John
My old MX60 said " hot" when the fan had failed.Todd
"MX 2 Hot (Very rare) Either the MX60 is too hot or its internal temperature
sensor is shorted. If this message appears, carefully check if the MX60’s heat
sink is extremely hot. The heat generated by the MX60, and therefore its
losses, is
Another option for grid tied with battery based systems, is to use flooded lead
calcium batteries which last 20 years and only need about 20 ml/ cell, added
every 3 years.
Todd
On Wednesday, February 28, 2024 12:35pm, "Roy Butler via RE-wrenches"
said:
And to add to Steve's good advice,
Wrenches,
I am receiving conflicting information about using a Mate 3s with legacy FX
inverters. Has anyone done this and was the 3s able to function correctly?
Thanks,
Todd
Sent from Finest Planet WebMail.
___
List sponsored by Redwood Alliance
And wifi at 2.4 gHz would work better than 5 gHz.
Todd
On Thursday, April 27, 2023 7:27am, "Drake Chamberlin via RE-wrenches"
said:
There is chicken wire under the stucco. The Gateway will be near a window,
which is not too far from the router. William's experience is encouraging. If
I can help with this as Michael built something similar to what I designed and
installed in 2001:
I plumbed small irrigation sprayers every ~15' around the perimeter of my
buildings under the eaves. This wets down the perimeter of the structures,
particularly the combustion zone where the
My 2005 yearly billing, net metering agreement with Pacific Power says nothing
about it being only valid for 20 years.
Todd
On Friday, March 3, 2023 8:46am, "William Miller via RE-wrenches"
said:
To my Friends on the Wrenches forum:
This is a question that likely can only be
Hey Jay,
This is this is only anecdotal but I have two UPS's with sealed batteries.
One sits where the battery is up right. The other one sits on its side and
the battery is horizontal. The longevity of the battery in the one oriented
upright is about double the other one.
Todd
On
If the grid is wired to AC2, then the inverter can charge off off that source
but not sell to it.
Todd
On Monday, December 19, 2022 7:50am, "Tump via RE-wrenches"
said:
I have neve heard that but I would connect the utility to the AC1 input as the
window is quite narrow then the
I 100% agree.
When I read the post about foolish, incredibly wasteful pv powered snow
melting systems, I was happy I'm retired.
Walking away from such nonsense is the only way I could sleep at night.
Todd
On August 10, 2022 6:44:43 PM Hilton Dier via RE-wrenches
wrote:
I just had an
I have a customer with a (now obsolete) Hartell DC 1/2" X 1/2" MIP solar hot
water circulation pump which is failing.
Does anyone happen to have one of these in their inventory? Or can anyone
suggest an alternate?
I remember March and ElSid used to also make similar DC pumps. It would be
13 matches