Re: [RE-wrenches] Over current Sqflex

2021-10-21 Thread Nick A Lucchese
Here’s that voltage vs efficiency chart you were referring to Jay. Nick > On Oct 21, 2021, at 9:05 AM, jay wrote: > > HI Mac, > > Its self limited as to current. > > Pump speed/gpm is based on voltage. I cant remember exactly but somewhere > above 80vdc is where it is running at full rp

Re: [RE-wrenches] Over current Sqflex

2021-10-21 Thread jay
HI Mac, Its self limited as to current. Pump speed/gpm is based on voltage. I cant remember exactly but somewhere above 80vdc is where it is running at full rpm/flow. Jay > On Oct 21, 2021, at 10:01 AM, Mac Lewis wrote: > > Hi Wrenches, > > Does anyone know if it's possible to over current

[RE-wrenches] Over current Sqflex

2021-10-21 Thread Mac Lewis
Hi Wrenches, Does anyone know if it's possible to over current an grundfos sq flex pump? It looks like it has a current limit of 10A but if more than 10A is available won't it just maximize pump speed? Thanks ___ List sponsored by Redwood Alliance Pay