Re: [RE-wrenches] under performing Enphase inverters

2011-11-04 Thread Jason Szumlanski
! Jason Szumlanski Fafco Solar From: re-wrenches-boun...@lists.re-wrenches.org [mailto:re-wrenches-boun...@lists.re-wrenches.org] On Behalf Of Mark Frye Sent: Thursday, November 03, 2011 6:23 PM To: 'RE-wrenches' Subject: Re: [RE-wrenches] under performing Enphase inverters I have a fleet

Re: [RE-wrenches] under performing Enphase inverters

2011-11-04 Thread SOLARPRO
We have had two 210's go dark. With SunPower 225. We keep one spare 210 in stock (have not had any 190's go yet). In a message dated 11/3/2011 2:27:30 P.M. Pacific Daylight Time, ma...@pvthawaii.com writes: For the first time, several weeks ago, after 40-50 Enphase installs, we’ve come

Re: [RE-wrenches] under performing Enphase inverters

2011-11-04 Thread August Goers
-wrenches-boun...@lists.re-wrenches.org [mailto: re-wrenches-boun...@lists.re-wrenches.org] *On Behalf Of *Jason Szumlanski *Sent:* Friday, November 04, 2011 6:26 AM *To:* RE-wrenches *Subject:* Re: [RE-wrenches] under performing Enphase inverters I’ve never installed a M210, but we have had dozens

Re: [RE-wrenches] under performing Enphase inverters

2011-11-04 Thread Jason Szumlanski
: re-wrenches-boun...@lists.re-wrenches.org [mailto:re-wrenches-boun...@lists.re-wrenches.org] On Behalf Of August Goers Sent: Friday, November 04, 2011 4:03 PM To: RE-wrenches Subject: Re: [RE-wrenches] under performing Enphase inverters We have over 1000 Enphase units installed of multiple types

[RE-wrenches] under performing Enphase inverters

2011-11-03 Thread Marco Mangelsdorf
For the first time, several weeks ago, after 40-50 Enphase installs, we've come across at least two M210s that we putting out consistently lower outputs than their immediate neighbors. We replaced the two mods first, which made no difference. Then, in consultation with Enphase, replaced the

Re: [RE-wrenches] under performing Enphase inverters

2011-11-03 Thread Mike Jessica Nelson
Yep, been there done that. Have also had multiple inverter failures. Mike Nelson MD Electric Solar, Inc. On Thu, Nov 3, 2011 at 2:27 PM, Marco Mangelsdorf ma...@pvthawaii.comwrote: For the first time, several weeks ago, after 40-50 Enphase installs, we’ve come across at least two M210s that

Re: [RE-wrenches] under performing Enphase inverters

2011-11-03 Thread Mark Frye
Sent: Thursday, November 03, 2011 2:27 PM To: 'RE-wrenches' Subject: [RE-wrenches] under performing Enphase inverters For the first time, several weeks ago, after 40-50 Enphase installs, we've come across at least two M210s that we putting out consistently lower outputs than their immediate