On Thu, 15 Nov 2001, Bob Staaf wrote:
Now this is getting strange. I am seeing the exact same error messages on
an entirely different server. This one is a Dell PowerEdge 2450 with a
Perc3 RAID controller. Again, a Fresh install of Enigma with all updates
EXCEPT for 2.4.9-13 as there are
On Thu, 15 Nov 2001, Bob Staaf wrote:
Now this is getting strange. I am seeing the exact same error messages
on
an entirely different server. This one is a Dell PowerEdge 2450 with a
Perc3 RAID controller. Again, a Fresh install of Enigma with all
updates
EXCEPT for 2.4.9-13 as there
I just discovered the cause of these errors. They correspond exactly to
when I ran /sbin/sfdisk -l to check my partitions. I ran the command
again and it produced the same errors. The server again is running a fresh
install of Enigma with all patches including kernel. It is a VA Linux 2240
Message -
From: Bob Staaf [EMAIL PROTECTED]
To: [EMAIL PROTECTED]
Cc: [EMAIL PROTECTED]
Sent: Thursday, November 15, 2001 3:46 PM
Subject: Re: 440GX Errors (Updated)
I just discovered the cause of these errors. They correspond exactly to
when I ran /sbin/sfdisk -l to check my partitions. I