[Repeater-Builder] RCA TCXOs for sale

2008-07-07 Thread n0qzv_jhorn
I have a set of TCXOs for a RCA 500 series repeater. They are 442.4 TX and 447.4 RX and were reworked by ICM. Please contact me directly with an offer. thank you James

[Repeater-Builder] RLC-4 DVR

2008-07-07 Thread Mike Mullarkey
I have a new in the box RLC-DVR sn#1125 that I want to trade for two RLC-ADM: Digital Audio Delay Module. Does anybody have some that they want to part with. Mike Mullarkey K7PFJ

Re: [Repeater-Builder] Re: Maxtrac Mic-Hook software option?

2008-07-07 Thread Camilo So
Sorry for the typo Trunking. - Original Message - From: Camilo So To: Repeater-Builder@yahoogroups.com Sent: Monday, July 07, 2008 4:43 PM Subject: Re: [Repeater-Builder] Re: Maxtrac Mic-Hook software option? Hi Bob I work in Motorola Plantation Depot for 8 years working

Re: [Repeater-Builder] Re: Maxtrac Mic-Hook software option?

2008-07-07 Thread Camilo So
Hi Bob I work in Motorola Plantation Depot for 8 years working on Maxtrac radio, They use to call the convention unit MAXTRAC and the trucking unit MAXTRACS with a "S" The Maxtrac 900 has a common audio problem specially the 900 trucking converted to conventional, on the volume control there is

Re: [Repeater-Builder] Re: Maxtrac Mic-Hook software option?

2008-07-07 Thread Bob M.
I ran my 900 MHz MaxTrac up. No setting in RSS for the hang-up box. I wonder why they did away with that. I also discovered that my radio has a serious receive audio problem at the moment; very weak, very distorted. Almost sounds off-frequency or like a cap has gone leaky and has upset the bias

[Repeater-Builder] Re: Maxtrac Mic-Hook software option?

2008-07-07 Thread skipp025
Hi Bob, This case is a Maxtrac 900 Conversion from trunking to conventional followed by a conversion to the Amateur Band Segment. I've used the plug jumper but in the case of this radio being used as a repeater receiver it would have been nicer to simply toggle the hook-switch in software ver

Re: [Repeater-Builder] Re: Maxtrac Mic-Hook software option?

2008-07-07 Thread Bob M.
It may have something to do with the way the radio was initialized, as in product line, model number, and the various features. Lots of bits, lots of combinations. I'll have to run my 900 MHz radio up and see what's there. I suppose this is one more reason why "those who know" just jumper the MI

Re: [Repeater-Builder] RadioShack Recalls Power Supplies Due to Electrocution and Fire Hazards

2008-07-07 Thread wd8chl
Mark Thompson wrote: > Description: The recall involves RadioShack 13.8V DC Power Supplies, > catalog numbers 22-507 and 22-508 with date codes from > 08A04 through 01A08. > > Date code format is MMAYY where MM is the month and YY is the year. The > catalog numb

[Repeater-Builder] Re: Maxtrac Mic-Hook software option?

2008-07-07 Thread skipp025
Hi Bob, Well an interesting thing happens when I try two different band Maxtrac Radios. The Off-Hook option appears in the Radio Wide Settings Table as you suggested, but only for the low UHF and VHF band radios. When I use the same software to read a Conventional 900 Radio the Off-Hook o

Re: Re: [Repeater-Builder] Re: RadioShack Recalls Power Supplies

2008-07-07 Thread Ron Wright
Gary, I got this info from a local licensed electrican who does a lot of home construction. He was not happy either. My wife owning a hair salon also has seen a number of required changes in your shop. I do not thing there is a breaker for each outlet, but more than one outlet wired to mult

[Repeater-Builder] Re: RadioShack Recalls Power Supplies

2008-07-07 Thread wb8art
I am not buying it. Seems over the top and you would never have enough breaker panel posistions for all of the needed outlets. Randy --- In Repeater-Builder@yahoogroups.com, Ron Wright <[EMAIL PROTECTED]> wrote: > > Bruce, > > Probably should kill this topic for it has radiacally changed from

Re: [Repeater-Builder] Re: RadioShack Recalls Power Supplies

2008-07-07 Thread Gary Glaenzer
Ron; That requirement (if it is correct) is NOT part of the NEC It would be a local thing, and quite frankly, I feel the original poster of that info may have incorrect information It would, among other things, limit a home to (42 - circuits used for other than outlets) receptacles, there being

Re: [Repeater-Builder] Re: RadioShack Recalls Power Supplies

2008-07-07 Thread Ron Wright
Bruce, Probably should kill this topic for it has radiacally changed from orginal posting and not really repeater related although AC power is a concern for about any repeater builder. I think one reason for separate wiring to each outlet is the way so many are wired using the little spring lo