Re: [Repeater-Builder] IFR Help

2006-01-17 Thread Q
The tone generator is the 4 digit thunmbwheel in the lower left of the front panel,format is XXX.X ,the pot sets the level. Make surethe int/ext mod is in internal and dial away! I sure do miss my IFR,had to sell due to hard times...73,Lee Jim McLaughlin wrote: > I recently inherited a IFR FM/A

Re: [Repeater-Builder] IFR Help

2006-01-17 Thread N9LLO
The 1000 series only has one tone generator, you must use it for PL OR test tone. If you want both you must use an external tone generator for the second tone.   Chris   YAHOO! GROUPS LINKS  Visit your group "Repeater-Builder" on the web.   To unsubscribe from

[Repeater-Builder] IFR Help

2006-01-16 Thread Jim McLaughlin
I recently inherited a IFR FM/AM 1000S service monitor. Yes a free thing! I do NOT have a manual yet but will in a couple of weeks. I am working on a couple of GTX's and want to check the sensitivy of a couple of modes. The CSQ generated signals work just fine but when I needed to add pl with the