Hi,
On Thu, Nov 10, 2005 at 08:07:00PM +, Sveinn Svavarsson wrote:
Hello I have a HP scanjet and I used the backend from cyberbaladeur.fr
and the scanner works almost fine but it only scans a small area about
145mm X 200mm instead of 220mm X 300mm which I would have expected it to be.
Hi,
On Fri, Nov 11, 2005 at 04:20:44PM +0300, Alexey Lobanov wrote:
In accordance with
http://www.sane-project.org/unsupported/xerox-workcentre-pe16.html , I
tried to use the Xerox PE16 machine with Samsung propietary backend.
The result is really funny: Samsung backend recognizes this
Hi,
On Fri, Nov 11, 2005 at 02:51:45PM -0500, David Mason wrote:
I am working on a project with an artist involving five scanners that
will all be running continuously. They are a range of consumer grade USB
scanners, eg, Canon FiDE 25, Epson, AGFA, etc.
I've got the basics going, but we
Hi,
On Sat, Nov 12, 2005 at 12:43:41PM +0100, Siewca Qbi wrote:
I have Artec's Scanner: AM12E+ and i find inside chipsets: AT015, AD
9816JS...
Maybe that help you...
Thanks. I added this information in our scanner list.
However, the chance that someone develops a driver for that old
parport
Hi,
I've just bought an epson 3490, and download the
sane-backends-2005-11-10.tar.gz and
sane-frontends-2005-11-10.tar.gz.
While the flatbed seems to work as expected, the transparency unit
doesn't.
I want to scan a negative film, but the resulting file is crossed
by a thick green line.
Oliver Schwartz wrote:
Hi,
I've just bought an epson 3490, and download the
sane-backends-2005-11-10.tar.gz and
sane-frontends-2005-11-10.tar.gz.
While the flatbed seems to work as expected, the transparency unit
doesn't.
I want to scan a negative film, but the resulting file is
Hi,
I'm using the tpu on the 3490 with backend-11-10. It works ok
though the scans seem quite dark compared to the original slide.
However adjusting the gamma settings on the scanned file gives a
nice 1024x768 display size. I'm very much a newbie at this so sorry
I can't give more detailed
Once it works you should start logging and do a preview scan and a
scan of a very small area in low resolution, both times using the
transparency adapter. The log files tend to get quite large, but it
should shrink to a manageable size after zipping. Please send it to
me directly, not to
Oliver Schwartz wrote:
Hi,
I'm using the tpu on the 3490 with backend-11-10. It works ok
though the scans seem quite dark compared to the original slide.
However adjusting the gamma settings on the scanned file gives a
nice 1024x768 display size. I'm very much a newbie at this so sorry
I