Nobody? I found this old discussion which seems to suggest the pixma devices
don't support auto-detection:
http://lists.alioth.debian.org/pipermail/sane-devel/2009-December/025674.html
If that's indeed the case, may I suggest updating the pixma backend so that it
doesn't advertise capabilities
Hi Olaf,
I just fixed the typo. Many thanks for your hint.
Cheers,
Rolf
Am 27.04.2017 um 13:32 schrieb Olaf Meeuwissen:
> Hi Rolf,
>
> I just noticed
>
> pixma.desc: Warning: `pixma's USB product id of `PIXMA TS5000 Series' is
> not a lowercase 4-digit hex number: `0x18022'
>
> in the make
Am Samstag, 22. April 2017, 19:02:57 CEST schrieb Dr.-Ing. Dieter Jurzitza:
> Dear listmembers,
> probably these questions have readily been asked over and over again, then
> my apologies:
>
> 1.) /etc/scanbd/scripts
> which scripts does this refer to? There are some scripts in /etc/scanbd,
> thos
Hi Aaron,
Sorry for not reading your whole thread before replying ;-)
Aaron Muir Hamilton writes:
> Sorry about the volume, third time is definitely the charm.
> Admittedly I struggled to grasp the style rules.
Style rules? If there are any, they're at a per file basis AFAICS :-(
Which reminds
Hi Aaron,
Thanks for the patch but it is incorrect on big-endian architectures.
>From 3.2.1 Image Transmission in the SANE API specification:
Conceptually, each frame is transmitted a byte at a time. Each byte
may contain 8 sample values (for an image bit depth of 1), one full
sample value
Hi Aaron,
Thanks for the patch. It's on its way to the Alioth repository.
Bonus points for a similar patch for JPEG "densities". TIFF is already
been taken care of.
Hope this helps,
--
Olaf Meeuwissen, LPIC-2FSF Associate Member since 2004-01-27
GnuPG key: F84A2DD9/B3C0 2F47 EA19 6
Hi Rolf,
I just noticed
pixma.desc: Warning: `pixma's USB product id of `PIXMA TS5000 Series' is not
a lowercase 4-digit hex number: `0x18022'
in the make output for the tools/ directory. I think you meant 0x1802
but can you check and fix this?
Thanks in advance,
--
Olaf Meeuwissen, LPIC-2