This error is not bad! The relative error is 1.5%, well within the usual
error of GGA (~2%)! What makes you think it's a bad result?
On Wed, 2005-04-13 at 15:14, Li-Ger Chen wrote:
>The pseudopotentials are good on bulk test (error<1 % )
>
> but on dimer , that is very bad the distance bet
The pseudopotentials are good on bulk test (error<1 % )
but on dimer , that is very bad the distance between atom-atom
Experimnet value : Nb2 : 2.07 Ang
Tc2 : 2.1 Ang
is someone could help me , thnks a lot :-D
Li-Ger Chen , National Taiwan
University
Two things:
1) In your fdf file, the line that reads
AtomicCoordinatesFormatFractional
should read
AtomicCoordinatesFormatFractional
instead. SIESTA is assuming that the coordinates are given in Bohr,
since it does not recgnize "AtomicCoordinatesFormatFractional" as a
keyword. This is one
Dear Prof
I am now doing calculation on graphite.I am herewith attaching my output file
.I observe the value of forces and pressure is high.Could you please anyone
help in this regard.
Sincerely
Kuganathan
-
Do you Yahoo!?
Yahoo! Small Business - Try our new
Chen,
Your results may differ greatly depending on the basis set, cutoff and
box size. For dimers or molecules, there is one kind of XC functional
that works better than others because it decays (exponentially, I think)
with distance. Right now I don't remember which one, I guess BLYP or
just LYP.
To wheather test the pseudopotential is good. I do bulk test ,
dimer test , cluster test on transition metalin bulk ,cluster(atom
numers >8 ), the siesta performed good enough, but in dimer , that is
worse enough
for example, the Nb dimer , experiment reveals that the atom - atom
distanc
6 matches