ghost atom
settings will have exact same basis in real space. Through this way you may
compare their groundstate total energies on same footing (they are
shifted with same amounts ).
Correct me if my explaination is wrong.
Best,
Jin Zhang
On 2/9/07, Zhanyu Ning <[EMAIL PROTECTED]> wrote
What do you mean "not stable"?
I have made O3 molecule calculation with pwscf months ago. Nothing weird.
The obtained bond length is about 1.44A, slightly larger than O2's(which is
1.23A)
Also, spin polarization has no effect in this case.
Jin Zhang
On 2/6/07, You Lin <[EMAIL
Your meshcutoff is too low (especially for GGA). Try to increase it to 200
or more until convergence reached. Also, a 0.01 deviation is not that bad.
Jin Zhang
On 2/2/07, Dr. Y. Lin <[EMAIL PROTECTED]> wrote:
On Thu, 1 Feb 2007, Oleksandr Voznyy wrote:
>> 1) Why is GGA pseudo-pot
Dear bipul,
If you're using ext2 fs, you can try to dump them out.
Google "ext2 dump" may help.
Regards,
Jin Zhang
Department of Physics,
Peking University,
PRC
bipul rakshit wrote:
I am facing a major problem. I installed siesta in my computer
successfully. But some ho
4 matches