Dear Pablo
Why you don't get these from http://www.icmab.es/siesta/Pseudos-Bases?
Of course you should login for download.
In addition, the name of the pseudopotential file must be the same as your
element and with capital letter. It means that for Carbon your file must be
named as C.psf not c.ps
Dear All:
There are four quantities (qc0, qcn0,Qsol,Qtot) about electric charge
in transiesta calculation(shown as following).
>From SIESTA: Efermi= -4.805
qc0 : 0.000
qcn0 : 456.635
nou,NGL,NGR:3731 832 832
TranSiesta: Qsol,Qtot: 483.480 957.0001.000
transies
Thank you very much Pablo!
As for the Ni issue, I used this functional previously (not SIESTA but a
different code), so I'm more or less confident that it should work for
systems I want to study. But thanks for pointing out, this is very useful
info.
2010/5/21 Pablo A. Denis
> sorry Vassili bu
Dear Pablo,
Do you also have an O.psf for DRSLL.
Many Thanks
John
Dr. John S. Tse
Professor
Canada Research Chair (Tier I)
Department of Physics and Engineering Physics
University of Saskatchewan
116 Science Place
Saskatoon, SK S7N 5E2
Canada
(Tel) +1 306 966 6410
(Fax) +1 306 966 6400
Quot
Dear colleagues,
Would anyone mind sharing any details of their experience with the new
functional type? How does it compare with PBE in terms of calculation speed,
what the possible caveats are, etc. Also, I'd be extremely grateful if
anyone could share their pseudos for C and H (and maybe some o
A similar tool is developed at the Alain Rochefort group in Montreal
http://nanostructures.phys.polymtl.ca/Home.html
I don't think they'll give you the code but they could also agree to do
simulations as coauthors.
Guys, don't mix plotting and calculating.
There was one more package for STM simulation based on SIESTA results
http://www.icmm.csic.es/jcerda/
But it is not free anymore as well. Probably you could get it by
contacting Jorge directly and including him as a coauthor.
To add to Marcos's suggestions, try to link your MPI compilation with the
sequential version of mkl.
MPI + threads can be tricky and they can certainly interfere with each other.
Although I do not foresee
this as the problem, it is something to try.
ITHREAD=-L/opt/intel/cmkl/10.1.1.019/lib/em
Also WSXM can produce constant current STM images from LDOS files of Siesta
(this is not mentioned in siesta manual).
Ruslan Zhachuk
The PLSTM is simple, it just integrates LDOS between Fermi and eU.
The package http://arxiv.org/pdf/cond-mat/0604540 can model tip shape,
material.
It also uses much more reasonable distances between tip and sample.
I think the package is not public.
Regards
Ruslan Zhachuk
2010/5/21 Ian Shuttlew
Henrik
I dont know if there is now another STM package for SIESTA, but last
year I successfully used the PLSTM.F package (bundled in the 'Util'
folder) to simulate STM images, obtaining:
Deduction of a three-phase model for the
(sqrt(3)xsqrt(3))R30°-Cu2Si/Cu(111) surface alloy
I. G. Shuttleworth,
Hi,
I saw this question had been up sometime before, but I am wondering if the
STM simulator described here http://arxiv.org/pdf/cond-mat/0604540 is still
in development or is available somewhere? It seems to give very good
results, and it would be nice if one could use it.
Regards
Henrik
Also, molden works pretty well and is quite lightweight. Funnily enough,
coded in Fortran :)
On Fri, May 21, 2010 at 1:12 PM, Mehmet Topsakal <
topsa...@unam.bilkent.edu.tr> wrote:
> use JMOL (http://jmol.sourceforge.net )
>
>
>
>
> 2010/5/21 Gregorio García Moreno
>
> Can anyone tell me how to
use JMOL (http://jmol.sourceforge.net )
2010/5/21 Gregorio García Moreno
> Can anyone tell me how to see the ANI file as a molecular graph?
>
> Thanks
>
ANI is identical to xyz. Any molecular viewer that reads xyz files (xmakemol is
the simplest one, gdis is what works best with SIESTA) can show those.
HTH,
Herbert
Gregorio García Moreno wrote:
Can anyone tell me how to see the ANI file as a molecular graph?
Thanks
--
Herbert Fruchtl
Se
Can anyone tell me how to see the ANI file as a molecular graph?
Thanks
<>
If you are really plagued that much about the error, you can try a few
things.
One of them is what Daniel Backlund has just suggested: lower the
optimization level. Sometimes faster is not better, especially when it comes
to ifort.
Second, perhaps this could be a problem with precision? By defaul
Kemal,
-O2 and -O1 are less aggressive optimizations than -O3. With -O3, the
compiler will do changes to the code at compile-time which can lead to many
sorts of errors - from sometimes unreliable numerical results due to
changing the order of instructions, to run-time errors sometimes. This is
do
Hey,
I keep getting the same error as well.
IFort and F90, won't matter.
But with F90, things are even worse.
The electron density never converges. For both cases, the serial and
parallel versions differ.
Is anyone aware of a reply by the development on the matter? This is not a
new topic as f
Hello,
Alexander, could you please explain why the -O2 or -O1 options?
What issue does it solve?
Cheers,
Kemal
20 matches