Dear all,
Have you ever done structural relaxation under Electric Field, using Siesta
2 or 3?
If so, could you share a sample file with me? I may be doing something
wrong, cause my runs never give any difference in structure with or without
E-field.
Thanks in advance, have a good day,
Kemal
Ruslan
It can do both. If you have a calculation with k-points it sums over them.
Check local_DOS.F for details, but it's rather straightforward.
Marcos
On Thu, Jun 10, 2010 at 9:44 PM, Руслан Жачук wrote:
> Dear Siesta code developers,
>
> once I posted this question, but nobody answers.
>
>
Dear Marcos
Â
Did you have an code that convert the pdos to a .dat file that the gnuplot can read. I can't compile the one that is in the tutorials (pdos). Thanks and my best regards.
Â
Luiz Adolfo
Em 10/06/2010 04:36, Marcos VerÃssimo Alves < marcos.verissimo.al...@gmail.com > escreveu:Ind
This is a matter of choice. Usually people choose the Fermi level for the
convenience of separating valence from conduction states, but of course you
can always set some other value to the zero of energy in your system. It
will only depend on the relevant quantities of your problem.
Marcos
On Thu
Luiz,
If you have calculated the PDOS through the block ProjectedDensityOfStates,
then all you need is the utility pdosxml. It is in the directory Util. Take
a look at m_orbital_chooser.f, which has to be changed to get whatever
information you need from the .PDOS file.
Cheers,
Marcos
On Thu, J
Hi Peter,
When I tried to compile your code using fortran compiler
following error appeared:
*HSX.f95:6.15:
use modul_log
1
Fatal Error: Can't open module file 'modul_log.mod' for reading at (1): No
such file or directory
*
I can't find in siesta code such a module.
I also thoug
Dear Siesta code developers,
once I posted this question, but nobody answers.
When calculating local density of states (LDOS) does Siesta count only
eigenstates at Gamma k-point or sums the states all over the Brillouin
zone???
I saw this question in mailing list, but also without answer.
Kind
Hello everyone,
When creating testing files for pseudos, should ionic configurations be
included?
Thanks in advance!
Rob
Siesterer's,
What exactly is the zero of the energy scale when you do a DOS/PDOS calculation?
The reason is, I have metal slabs, and I've calculated their work
functions (I'm not using MACROAVE, though). I want then to present DOS
(or rather the surface PDOS) of these slabs, and I want to make th
Dear Marcos,
Really thank you very much.
But could you please give some explains about:
"There is also an option, which is padding variables with zeroes to
get them properly aligned, which improved my performance quite a bit."
what you mean the 'padding variables with zeroes' ?
Thank you very much
Indeed. Nevertheless, THAT piece of information was not in your previous
email... and it was the really relevant one, since a change in electronic
temperature will not produce runtime errors.
Golden rule for computational physics: be Zen and do one change at a time :)
Marcos
2010/6/10 sonu kumar
Hi Shihzheng,
I suppose it has worked, then :) The problem when you update a whole system
is that sometimes libraries change version and therefore features inside it
change as well. Ideally you should stick to a certain distribution for as
long as you can and install the updates forf that specific
12 matches