Re: [SIESTA-L] problem with Ge in LDA with Siesta

2014-02-11 Por tôpico Roberto Guerra
Hi, I just wish to note that in all the cases I have treated SIESTA produces band gaps much larger than plane-wave codes. For example SiO2 LDA band gap is about 7eV in SIESTA and 5.5eV in ESPRESSO. Maybe this is related to the SIESTA method itself, or to a non-trivial choice of the basis set.

Re: [SIESTA-L] problem with Ge in LDA with Siesta

2014-02-09 Por tôpico Riccardo Rurali
- Mensaje original - De: "Roberto Guerra" Para: siesta-l@uam.es Enviados: Domingo, 9 de Febrero 2014 11:43:45 Asunto: Re: [SIESTA-L] problem with Ge in LDA with Siesta > I just wish to note that in all the cases I have treated SIESTA produces > band gaps much larger

Re: [SIESTA-L] problem with Ge in LDA with Siesta

2014-02-09 Por tôpico Roberto Guerra
Hi, I just wish to note that in all the cases I have treated SIESTA produces band gaps much larger than other plane-wave codes. For example SiO2 LDA band gap is about 7eV in SIESTA and 5.5eV in ESPRESSO. Maybe this is related to the SIESTA method itself, or to a non-trivial choice of the basis

Re: [SIESTA-L] problem with Ge in LDA with Siesta

2014-02-06 Por tôpico FEDERICO IORI
Hi all. Just a comment: a norm conserving LDA pseudo with plane waves (without any semicore states, nonlinear core correction) nor spin orbit coupling should give a semimetal for the Ge. Which flavour of pseudo are you using for Abinit? Thanks Federico. > Hi Riccardo > > We have same kind of pro

Re: [SIESTA-L] problem with Ge in LDA with Siesta

2014-02-06 Por tôpico Rafi Ullah
Hi Riccardo We have same kind of problem/observation. We are using Siesta with LDA (DZP basis) and it produces an indirect band gap of 0.70 eV. We have also tested with plane waves basis using Abinit (cutoff = 95 Ry) and found 0.58 eV. Chelikowsky et el. (PRB, 40, 1989) using plane waves report an

Re: [SIESTA-L] problem with Ge in LDA with Siesta

2014-02-06 Por tôpico Hela Ouali
On 06/02/2014 15:56, Riccardo Rurali wrote: On 2/6/14 4:00 PM, Hela Ouali wrote: On 06/02/2014 15:43, Riccardo Rurali wrote: Dear Siesters, I am having trouble with Ge in LDA with Siesta. As is well-known, Ge is a pathological case within DFT-LDA: the gap shrinks so much that is becomes negat

Re: [SIESTA-L] problem with Ge in LDA with Siesta

2014-02-06 Por tôpico Riccardo Rurali
On 2/6/14 4:00 PM, Hela Ouali wrote: On 06/02/2014 15:43, Riccardo Rurali wrote: Dear Siesters, I am having trouble with Ge in LDA with Siesta. As is well-known, Ge is a pathological case within DFT-LDA: the gap shrinks so much that is becomes negative, i.e. Ge is metallic in LDA. However, I'

Re: [SIESTA-L] problem with Ge in LDA with Siesta

2014-02-06 Por tôpico Hela Ouali
On 06/02/2014 15:43, Riccardo Rurali wrote: Dear Siesters, I am having trouble with Ge in LDA with Siesta. As is well-known, Ge is a pathological case within DFT-LDA: the gap shrinks so much that is becomes negative, i.e. Ge is metallic in LDA. However, I'm having problems in recovering this

[SIESTA-L] problem with Ge in LDA with Siesta

2014-02-06 Por tôpico Riccardo Rurali
Dear Siesters, I am having trouble with Ge in LDA with Siesta. As is well-known, Ge is a pathological case within DFT-LDA: the gap shrinks so much that is becomes negative, i.e. Ge is metallic in LDA. However, I'm having problems in recovering this behavior with Siesta and I get gaps of 0.4-